Advertisement

COMMUNICATING VARIABLE
SPEED FAN COIL PURON®
REFRIGERANT
PREMIUM ENVIRONMENTALLY SOUND
The FE4A is the premium air handler combining the proven
technology of Bryant fan coils with the environmentally sound
refrigerant, Puron®. The FE4A achieves an operation
advantage because the ECM (Electronically Commutated
Motor) combined with a Quantum Plus heat pump with Puron is
highly efficient at all possible operating speeds, and delivers the
precise amount of airflow desired over a wide range of duct
static pressure conditions.
The FE4A comes with state of the art smart diagnostics
capability. This enables faster troubleshooting providing ease of
service and repair. The FE4A also provides a 4-wire hook up
with matching outdoor unit and the Evolution Control. This
makes installation simpler and a lot quicker than with
conventional fan coils. The FE4A's advanced technology allows
the fan coil to self-configure with a matching outdoor unit and
the Evolution Control, cutting down on installation time.
Other features homeowners appreciate are quiet operation of
the FE4A, including the soft ramp up at the beginning of a
heating or cooling cycle, and its soft ramp down when the duty
cycle is complete. Annoying sounds from sudden changes in
airflow are reduced for worry free comfort. When used in
continuous fan mode, the FE4A can operate quietly at very low
levels of airflow for gentle reduction of temperature differences
between areas of the home and within each individual room
from floor to ceiling. In addition, when used in conjunction with
Bryant air cleaners, the FE4A provides continual cleansing of
the air while quietly operating in continuous fan duty, for the best
in indoor air quality.
The FE4A is loaded with other popular features. The
Thermostatic Expansion Valve (TXV) reliably meters refrigerant
at all operating conditions during cooling mode providing
excellent compressor protection. Grooved copper tubing,
louvered aluminum fins, and the large face areas of the FE4A
refrigerant coils provide superior efficiency, for high SEER and
HSPF performance. Robust, corrosion resistant and highly
draining condensate pans provide for excellent condensate
control. All components are protected within a rugged,
prepainted metal cabinet lined with super thick, high density
insulation and vapor barrier. The unit exterior features sweat
refrigerant connections for simple leak free performance,
A02332
multiple electrical entry for both high and low voltage service to
simplify installation. Field-installed heaters are also available,
ranging from 5-kw to 30-kw.
For the best in efficiency and Environmentally Sound operation,
comfort, ease of installation and reliable performance, the FE4A
can't be beat.
MODEL FE4A
Sizes 002 thru 006
FE4A
FAN COIL
Form No. PDS FE4A.18.1

Advertisement

Table of Contents
loading

Summary of Contents for Bryant fe4anf005

  • Page 1 PREMIUM ENVIRONMENTALLY SOUND FAN COIL The FE4A is the premium air handler combining the proven technology of Bryant fan coils with the environmentally sound refrigerant, Puron®. The FE4A achieves an operation advantage because the ECM (Electronically Commutated Motor) combined with a Quantum Plus heat pump with Puron is highly efficient at all possible operating speeds, and delivers the...
  • Page 2 FEATURES Smart Diagnostics • Self configuring (ease of installation) • Easier troubleshooting, providing faster service and repair. • Puron®, Environmentally Sound Refrigerant • Puron-ready TXV • Efficient ECM makes the most of the outdoor unit’s performance capabilities • Static pressure-adapting ECM for dependable airflow •...
  • Page 3 SPECIFICATIONS MODEL FE4A SIZE 006* SHIPPING WEIGHT (Lb) REFRIGERANT Puron (R-410A) Refr. Metering Device Size 2 Ton 3 Ton 4 Ton 4 Ton COIL Type Slope Rows - Fins/In. 3 - 14.5 Face Area (sq-ft) 3.46 3.46 5.93 7.42 MATCHES OUTDOOR UNIT SIZES Nominal Cooling Tons 1.5, 2, 2.5, 3 2, 2.5, 3, 3.5...
  • Page 4 —4—...
  • Page 5 —5—...
  • Page 6 1050 CFM 1.00 IN. H2O 1225 CFM 1.00 IN. H2O 875 CFM 1.00 IN. H2O 1050 CFM 1.00 IN. H2O FE4ANF005 1225 CFM 1.00 IN. H2O 1400 CFM 1.00 IN. H2O 1050 CFM 1.00 IN. H2O 1225 CFM 1.00 IN. H2O...
  • Page 7 PERFORMANCE DATA Continued MINIMUM CFM FOR ELECTRIC HEATER APPLICATION HEAT PUMP Heater Size KW UNIT UNIT SIZE SIZE 9, 10 24, 30 Heater Only 1025 — — — — — — 1050 1125 — 1000 1050 1125 1225 — Heater Only 1100 —...
  • Page 8 ACCEPTABLE RANGE TOO HIGH RETURN STATIC PRESSURE (DIFFICULT TO MAKE TRAP) RETURN STATIC PRESSURE, IN.W.C. A96052 Acceptable Duct Conditions For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed with duct systems which fall within the “Acceptable Range” illustrated above. —8—...
  • Page 9 PERFORMANCE DATA Continued COOLING CAPACITIES (MBtuh) COIL REFRIGERANT TEMPERATURE (°F)* EVAPORATOR Evaporator Air — Entering Wet-Bulb Temperature (°F) UNIT SIZE 0.04 0.07 0.10 1000 0.11 1250 0.13 0.20 1000 0.22 1200 0.25 1400 0.27 0.04 0.06 1150 0.07 1500 0.10 1700 0.11 1050...
  • Page 10 * Saturated suction leaving evaporator coil. 5. SHC is based on 80°F db temperature of air entering coil. Below 80°F Sensible Heat Capacity (1000 Btuh) subtract (corr factor x CFM) from SHC. Above 80°F db, add (corr factor x CFM) to SHC. Gross Cooling Capacity (1000 Btuh) BF—Bypass Factor SHC CORRECTION FACTOR...
  • Page 11 PERFORMANCE DATA Continued AIRFLOW PERFORMANCE CORRECTION FACTORS The FE4A Airflow Performance table was developed using fan coils with 10-kw electric heaters (2 elements) in the units. For fan coils with heaters made up of a different number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure.
  • Page 12 ACCESSORY LIST ITEM ACCESSORY PART NO. FAN COIL SIZE USED WITH FE4A Disconnect Kit KFADK0201DSC Cooling controls and heaters through 10-kW Downflow Conversion Kit (Slope) KFADC0201SLP Downflow Conversion Kit (A-coil) KFADC0401ACL 002, 005, 006 Downflow Base Kit KFACB0201CFB KFACB0301CFB 003, 005 KFACB0401CFB Filter Kit (12 Pack) KFAFK0212MED...
  • Page 13 ELECTRICAL DATA UNITS WITHOUT ELECTRIC HEATER BRANCH CIRCUIT UNIT Min Wire Fuse/Ckt Bkr SIZE VOLTS-PHASE AMPS Size Awg* Amps 208/230-1 208/230-1 208/230-1 208/230-1 * Use copper wire only to connect unit. If other than uncoated (nonplated) 75°F ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used consult applicable tables of the National Electric Code (ANSI/NFPA 70).
  • Page 14 —14—...
  • Page 15 —15—...
  • Page 16 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: New Form PDS FE4A.18.1 —16— © 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 12FE-4A0 12-03...