The Netherlands 2.2 LED-status display 2.3 Technical specifications Declares the conformity of the product: Charging stations of Type ICU Eve Mini 3. Mounting and connecting 3.1 Installation and connection Following the Euopean Directives: 3.2 Requirements for assembly and installation 7...
The warranty on products and accessories expires in the following cases: • Failure to follow these Installation and Operati- The ICU Eve Mini charging station is intended ex- on Instructions clusively for charging of electric vehicles without the •...
Terminal block for tethered cable Always make reference to the serial number when contacting to Alfen ICU so that you receive the fas- SIM Card Slot test support. Terminal block for power cable...
Product 2.2 LED-status The ICU Eve Mini (with display) comes with four LED icons and the non-display version with one LED which indicates the status of the charging session. Please find below an overview of the different states: Display LEDs Meaning •...
Product 2.3 Technical specifications Input/power supply Power supply Min. 3 x 4 mm² (1-phase, 16 A) / max. 5 x 6 mm² (3-phase, 32 A) Rated voltage 230 V / 400 V Mains connection Min. 25 A 1-phase 230 V 50 Hz (3.7 kW version); min. 40 A 1-phase 400 V 50 Hz (7.4 kW version);...
Page 6
RFID (NFC) Mifare 13.56 Mhz, DESFire, integrated (optional) Internet / Network ability GPRS, TCP/IP Communication protocol OCPP 1.5 (JSON) Backend-connection ICU Connect (optional) or other backend (on request) Communication with Smart Meter UTP cable with RJ11-plug Operating conditions Operating temperature -25°C to 40°C...
3.1 Installation and connection 3.2 Requirements for assembly and installation Read these instructions before installing the char- ging station carefully. Alfen ICU B.V. are not liable NOTICE for any consequential damages that occur due to the use of this manual.
Installation of the charging station 3.3 Mechanical installation NOTICE Installation requirements may vary for different The following tools and materials to install the ICU locations. Eve Mini: When selecting the installation site the following • Spirit level conditions must be assessed: •...
Fig. 1: Attachment to the wall 1. Insert the nylon wall plugs into the four holes 2. Attach the ICU Eve Mini on the wall with four Fig. 2: Connecting terminals of the1-phase and 3-phase version M8 x 12 mm screws...
8. Remove the insulation of the power supply 5. All LEDs go out and/or fixed cable using a wire stripper so that 6. The ICU Eve Mini is now ready for charging the cores are sufficiently exposed to be able to be installed in the connecting terminals 4.3 Putting into operation (without dis-...
If you signed a contract with a back end supplier or It may be possible that a MAC address is required. with Alfen ICU B.V. (for provision of ICU EZ back This is stated on the FAT report of the charging end services), your charging station is configured to station.