Electrical Work - Toshiba RAS-3M18S3AV-E Installation Manual

Multi-split type outdoor unit
Hide thumbs Also See for RAS-3M18S3AV-E:
Table of Contents

Advertisement

Outdoor Unit
CAUTION
This product contains fluorinated
greenhouse gases covered by the Kyoto
Protocol.
• Chemical Name of Gas: R410A
• Global Warming Potential (GWP) of gas:
2088
1. Stick the enclose refrigerant label adjacent
to the charging and/or recovering location.
2. Clearly write the charge refrigerant quantity
on the refrigerant label using indelible ink.
3. Prevent emission of the contained
fl uorinated greenhouse gas.
Ensure that the fl uorinated greenhouse gas
is never vented into the atmosphere during
installation, service or disposal.
If any leakage of the contained fl uorinated
greenhouse gas is detected, the leak
must be stopped and repaired as soon as
possible.
4. Only qualifi ed service personnel are
allowed to access and service this product.
5. Any handling of the fl uorinated greenhouse
gas in the product, such as when moving
the product or recharging the gas, must
comply with (EC)
Regulation No.842/2006 on certain
fl uorinated greenhouse gases and any
relevant local legislation.
6. Contact dealers, contractors, etc., for any
questions.
Pre-charged Refrigerant
1
at Factory [kg], specified
R410A
in the nameplate
kg
Additional Charge on
2
kg
Installation Site [kg]
kg
Periodical inspections for refrigerant leaks
may be required depending on European or
local legislation.
Insulation of the Refrigerant Pipes
• Insulate the refrigerant pipes for liquid and gas separately.
Heat-proof bubble polyethylene
Gas Leak Inspection
• Perform a gas leak inspection for the fl are nut connections, valve stem
connection, and service port cap without fail.
• Use a leak detector exclusively manufactured for R410A.
Flare nut connections
(Indoor unit)
Service port cap
connection
Valve stem cap
connection
* Check point example (RAS-3M18S3AV-E)
Performing Additional Installation of an Indoor Unit
1. Collect refrigerant from the outdoor unit.
2. Turn off the circuit breaker.
3. Perform additional installation referring to the procedure from "Refrigerant
Piping Connection" on the previous page.
7

Electrical work

WARNING
• Be sure to comply with local regulations/
codes when running the wire from the
outdoor unit to the indoor unit.
(Size of wire and wiring method etc.)
• A lack of electrical capacitance or incorrect
wiring may cause an electric shock or a
fi re.
• To make sure that the wiring connection
are secure, use designated cables.
• Fix the cables securely so that no external
force applied to the cables may effect the
terminals.
• If wiring connections are incomplete or
cables are not fi xed securely, it may cause
a fi re.
• Be sure to ground the outdoor unit.
• Incomplete grounding may lead to an
electric shock.
9
Installation Manual
Flare nut connections
(Outdoor unit)