Download Print this page

jablotron JA-60WEB Installation Manual page 3

Advertisement

3.4
Gateway IP address setting
If DHCP is disabled, set the gateway IP address by sequence:
where:
Example: to set Gateway IP address 192.168.33.1 enter 93 192 168 033 001
Factory default setting: Gateway IP address 192.168.1.1
3.5
Reset to default setting
Entering 96060 will cause a return to the factory default settings, see 6 (the IP address and all unsent
data will be erased).
4
Web server remote access
All parameters of the JA-60WEB communicator can be set via an internet browser. Full support is
possible using MS Internet Explorer version 6 or higher. Setting can be done locally as well as from an
outside network (if it is enabled – please consult the network provider / supervisor).
4.1
Access to the web server
After setting has been done according to section 3 , enter the IP address of the communicator into
your web browser (for example: http://192.168.1.23), the login dialog will appear.
Factory default setting:
Name: jablotron
Password: jablotron
Note:
The name and password can be customized (see 4.1.3)
By clicking on the reset button which can be found on the most pages, you will reset the
settings to their original values.
4.1.1 Panel
In the panel page the user can:
Monitor the control panel
Operate Hot keys for controlling the control panel quickly
Enter programming or operating sequences in the Sequence input field
See the status and operate the outputs (AUX1-AUX3) and see the status of the input (INP)
4.1.2 Events
To see the 127 latest events
4.1.3 Communicator
In the communicator page the user can:
Configure the network settings such as DHCP, IP address, Netmask and gateway
Set the Idle time for auto logoff, and HTTP port
Set the Function of the input (off - the status of the input will be only shown in the Panel
Page, tamper – when connected to GND, the control panel will trigger the tamper alarm)
Customize Login Name and Password
4.1.4 Control panel
This page is accessible only when the control panel is in programming mode (P). It enables full
setting of the control panel. A detailed description of the parameters can be found in the control
panel manual.
JA-60WEB communicator
93 xxx xxx xxx xxx
xxx xxx xxx xxx is the IP address
-3 -
MHO51103

Advertisement

loading