Nikon D60 Repair Manual page 85

Hide thumbs Also See for D60:
Table of Contents

Advertisement

Items
Standby / consumed
current
Operation time
Consumption current
accumulated
Clock accuracy
(20±5℃)
BC level
Bulb battery life
Judgment standard
Main SW / OFF: 200μA or less (when inner battery is fully
charged)
Main SW / ON (Half-release timer: OFF): 200μA or less (when
inner battery is fully charged)
Main SW / ON (Half-release timer: ON): 200mA or less (when
no operations made)
Main SW / ON (TFT monitor ON): 300mA or less
Lens scan
8-55/3.5-5.6G: 700 ms or less
     
Release without memory card 
(8-55/3.5-5.6G): 95ms or less
(between mirror up and down)
    
Lens scan
8-55/3.5-5.6G: 850 mAs or less
     
Release without memory card 
(8-55/3.5-5.6G): 320mAs or less
(between mirror up and down)
    
Difference par month: ±90 seconds
Level 5: 5 lights up 
Level 4: 4 lights up 
Level 3: 3 lights up 
Level 2: 2 lights up 
Level :  light up 
Level 0:  light blinking Charge remaining: 0%
 hour and 40 minutes or more
- R4 ・    -
Charge remaining: 70 ~ 00%
Charge remaining: 50 ~ 69%
Charge remaining: 35 ~ 49%
Charge remaining: 20 ~ 34%
Charge remaining:  ~ 9%
logo_Q0650_forGraphic
071004_Gdesign_ito
INC
VBA21001-R.3753.A
Remarks
Power source: 7.8V
Luminance: EV2
Lens:
8-55/3.5-5.6G
Oscilloscope:
measured by +
current probe
Power source:
7.8V+0.3Ω
Luminance: EV2
Oscilloscope:
measured by +
current probe
Wave clock
Check the level in
the LCD control
panel on top of
camera or TFT
battery information
Communication-
capable battery tool
When battery is
fully charged
Clock

Hide quick links: