FOCUS CONTROL
Press FOCUS FAR : focus far and release the key to stop focusing.
Press FOCUS NEAR : focus near and release the key to stop focusing.
PRESET POINT SETUP
The speed dome camera enables 80 preset points. Preset function is to save
the address information (such as PTZ pan/tilt, focus and etc) to the memory
so that you can quickly adjust the dome and PTZ to the correct position,
and when necessary to view life monitoring.
Setup Steps:
① Select the desired speed dome camera.
② Use the joystick (on the control keyboard) and move the speed dome
camera to the desired preset point.
③ Use the zoom control to adjust the monitoring display.
④ Enter preset number (1~32, 35~82), and press SET PRESET key, the
LCD will display
⑤ Press SET PRESET key, to enable storage and press CLEAR key to
disable storage.
⑥ Repeat the steps 2~5 again, to setup more preset points.
CALL PRESET POINT
Enter the assigned preset number and press GO PRESET key, the LCD
GO
PRESET
will display:
to that specified preset point.
st
Example: 1
preset point = 1 + GO PRESET
th
28
preset point = 2
CHANGE PRESET POINT
To change the preset point, please follow the setup guide in the "PRESET POINT
SETUP".
PATTERN RUN
This function is designed to scan the preset points in order. Each group is
allowed to set up 32 preset points for moving speed and retention time. The
Auto Pan has a total of 6 setting groups, but only 4 are programmable. Group
from 1~4 is allowed to set up to 32 preset points and Group 5~6 are not
programmable by user (3 preset points).
The 5th and 6th group is fixed (not programmable)
* The 5th group functions as a simple continuous rotational manner; included
are 1st, 2nd, and 3rd preset points.
* The 6th group functions as a simple continuous rotational manner; included
are 4th, 5th, and 6th preset points.
SAVE
TO
PRESET
XXX
?
:
XXX
, and the speed dome camera will move
8 + GO PRESET
17
.