1. Safety Precautions CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN! CAUTION : TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. It is advised to read the Safety Precaution Guide through carefully before operating the product, to prevent any possible danger.
2. Symbol Description 1. Function keys are shown by, framed capital boldface print letters. Example: ENTER , AUTO FOCUS , etc. 2. Function key “+” indicates the order sequence. Example: 8 + ENTER meaning, press the function key “ 2 “, “...
3. Features Speedy response with 22x optical auto-focus zoom lens and 16x Electronic Zoom or 35x optical auto-focus zoom lens and 16x Electronic Zoom. Day & Night (IR Cut Filter Change Mechanism). Auto Iris and Manual Iris Control. Advanced DSP Camera, including Auto White Balance, Backlight Compensation and Auto Iris Control.
5. Component and Structure Description Indoor Type ① Transparent Cover/ Black Housing ② Machine Housing ③ Embellish Cover ④ ID Number/ Protocol/ Baud Rate Setting (Please Refer to Pg8-9). ⑤ Alarm Input or Output / Video Output / Power Input Terminal (Please Refer to Pg11)
Page 8
Outdoor Type Wall Mount Pendant Mount Corner Mount ① Wall Mount Bracket/ Pendant Mount Bracket/ Corner Mount Bracket ② Machine Housing ③ Transparent Cover ④ ID Number/ Protocol/ Baud Rate Setting (Please refer to Pg8 and Pg10). ⑤ Alarm Input or Output / Video Output / Power Input Terminal (Please refer to Pg12).
6. Camera Setting Indoor Type Outdoor Type DIP Switch setting, shown below: Setting 000, then the image display will show: DEVICE N/A. Does not affect setup.
Indoor Type SW1: ID Number Setting Connection of up to 127 Speed Dome Cameras, each camera has its own ID Number. SW2: Protocol Settings Settings Switch Number Protocol #1 #2 #3 #4 Off Off Off Off NATIVE On Off Off Off PELCO Off On Off Off Reserved...
Outdoor Type SW1: ID Number Setting Connection of up to 127 Speed Dome Cameras, each camera has its own ID Number. SW2: Baud Rate Settings Settings Switch Number Baud Rate #1 #2 #3 #4 Off Off Off Off 9600 BPS On Off Off Off 4800 BPS Off On Off Off...
Page 12
Indoor Type Terminal base Connection, Data Line, and Signal Line Regulation 1. Power Input Terminal - DC 12V Input and power consumption of 1.1A. 2. Video Output Terminal - Video Signal Output: CVBS 1. 0Vp-p 75Ω BNC. 3. The Speed Dome Camera is equipped with 6 external alarm triggering input and 2 sets of alarm output (1 set NO and 1 set NC).
Page 13
Outdoor Type Terminal base Connection, Data Line, and Signal Line Regulation. 1. Power Input Terminal DC 12V Input and power consumption of 2.5A. AC 24V Input and power consumption of 2.2A. Video Output Terminal Video Signal Output: CVBS 1.0 Vp-p 75Ω BNC. 2.
8. System Assembly Simple to install, the system supports connection of numerous devices (Ex.: Speed Dome Camera, P/T/Z Receiver, and etc.) Connect the double twisted cable from the keyboard to the RS-485 terminal, and video signal to the monitor, DVR or multiplexer to complete the main system connection.
9. Operation Select and switch Outdoor Speed Dome Camera CAMERA and SWITCH DEVICE Use numeric key + CAM key Enter the desired number n camera and press CAM key, the speed dome selected by the user to control will appear on the LCD display: ⎡...
Page 18
FOCUS CONTROL Press FOCUS FAR : focus far and release the key to stop focusing. Press FOCUS NEAR : focus near and release the key to stop focusing. PRESET POINT SETUP The speed dome camera enables 80 preset points. Preset function is to save the address information (such as PTZ pan/tilt, focus and etc) to the memory so that you can quickly adjust the dome and PTZ to the correct position, and when necessary to view life monitoring.
Page 19
AUTOPAN SETUP Range: 1~4 GROUP Range: 1~32 INDEX Range: 80(1~33, 35~82) or POSITION Range: 1~15 (higher the value, faster the speed) SPEED Range: 1~128 DWELL TIME (sec) Setup Steps: ① Select a desired group number (1~4 groups). ②...
Page 20
AUTO SCAN Activate Auto Scan Under control mode (assume device=1), when the LCD displays: ⎡ ⎤ DEVICE , enter 9 9 + G0 PRESET key, the speed ⎢ ⎥ ⎣ ⎦ dome camera will slowly precede 360° auto scan. Deactivate Auto Scan Enter 9 6 + GO PRESET key, or push the joystick to stop auto scan.
10. OSD Operational Description OSD TREE STRUCTURE MAIN MENU ITEM SELECTION NOTES ID DISPLAY ON/OFF STATES SET UP FLIP FUNCTION ON/OFF TITLE DISPLAY ON/OFF Use number 0 as substitute TITLE SET xxxxxxxx for capital letter alphabet O Iris Level: CAMERA SET UP EXPOSURE 000~028 22x: 000~220...
Page 22
MAIN MENU ITEM SELECTION NOTES BRIGHTNESS 000~099 IMAGE SET UP FLICKERLESS ON/OFF SHARPNESS 000~015 Applicable only to high MIRROR ON/OFF resolution cameras COLOR display is applicable COLOR ON/OFF only to cameras without DAY/ NIGHT function. ALARM PIN 001~006 Alarm Serial Number ALARM SET UP ALARM SWITCH ON/OFF...
11. Quick Operational Reference Table Functions Method of Operation Upward Rotation Push the Joystick Forward (upward image monitoring) Downward Rotation (downward image monitoring) Push the Joystick Backward Leftward Rotation (leftward image monitoring) Push the Joystick Leftward P/T/Z Control Rightward Rotation Push the Joystick Rightward (rightward image monitoring) Zoom Tele...
Page 24
Menu Setup Mode Functions Method of Operation Cursor Up Push the Joystick Forward FOCUS NEAR Cursor Down Push the Joystick Backward FOCUS FAR Menu Enter IRIS OPEN Menu Exit IRIS CLOSE Decrease (-) Push the Joystick to the Left Increase (+) Push the Joystick to the Right Turn Joystick Clockwise Turn Joystick Anti-Clockwise...
12. Appendix Trouble shooting 1. Speed Dome Camera switched OFF Check whether the power supply is correctly connected: Indoor Type - DC12V Outdoor Type - DC12V or AC24V. Check whether the fuse has been burned. Check whether or not the 20PIN the camera foot has fallen off. Check whether or not the outdoor type 2PIN power cable has fallen off.
13. Specifications Manual Operation: Horizontal Rotational Speed 1°~150° Per Sec. : Vertical Rotational Speed 1°~100° Per Sec. Manual call on preset points: Horizontal Rotational Speed 1°~300° Per Sec. Vertical Rotation Speed 1°~200° Per Sec. Preset Points Retention period 0~128 Sec. Horizontal rotation of 180°...
Page 27
Minimum Illumination 22X HR Normal Mode: 0.2Lux @F1.6 22X HR-EX (ICR) Normal Mode: 0.12 Lux @F1.6 Night Mode: 0.05 Lux @F1.6 22X NR (ICR) Normal Mode: 0.007 Lux @F1.6 Night Mode: 0.03 Lux @F1.6 35X HR-EX (ICR) Normal Mode: 0.12 Lux@F1.6 Night Mode: 0.05 Lux@F1.6 S/N Ratio More than 48dB...
Page 28
Electrical - Outdoor Type DC Power Supply AC100V ~ AC240V (DC12V TYPE) Power Input DC12V/ 2.5A or AC24V/ 2.2A Power Consumption 27W@DC12V or 31W@AC24V by power type Heater Temperature Switch ON:<15℃±4℃ OFF:>25℃±3℃ Controller Interface RS-485 Alarm Input 6 Alarm Inputs Alarm Output 1Set NC (Normal close) 1Set NO (Normal open)