Disable Clear Configuration Key Sequence - Motorola EWB100 Deployment Manual

Compact voice over wireless communication device
Hide thumbs Also See for EWB100:
Table of Contents

Advertisement

EWB100 Usage and Deployment Guide

14.6 Disable Clear Configuration Key Sequence

If set, the capability to clear a configuration using a multiple key sequence is
disabled. The function is controlled by the following configuration bit in the "misc
new2" command:
The bit value is 0x0800
The default is to enable the sequence.
14.7 Return to Default Profile when inserted into charging cradle
If set, when the device is inserted into the charge cradle it will set the profile to
the "default profile" (which defaults to profile 0 but can be set to any profile). The
function is controlled by the following configuration bit in the "misc new2"
command:
The bit value is 0x200.
The default is not to return to the default profile.
14.8 Simplfied Profile Selection Mode
If set and if the SAPP button is configured for Profile Switching mode, then
pressing the SAPP button will rotate through the enabled profiles without any
prompt other than the profile alert. Each profile is assumed to be configured for a
different WTT channel and so this provides an easy way to scroll through up to 8
WTT channels (1 per profile). No confirmation is required; the the device will
simply stay indefinitely on the last selected channel. The function is controlled by
the following configuration bit in the "misc new2" command:
The bit value is 0x0040.
The default is to not to use the simplified mode..
14.9 Set current profile as default profile
If set, the device will save to flash any profile changes. The last profile selected
by a user will become the "default" profile on any subsequent system restarts.
The default is disabled. The function is controlled by the following configuration
bit in the "misc new3" command:
The bit value is 0x0002.
The default is to disable this mode.