Imada DS2 Instruction Manual

Imada DS2 Instruction Manual

Digital force gauge

Advertisement

2 YEAR WARRANTY
(RESTRICTIONS APPLY)
Imada, Inc. warrants its products to the original purchaser to be free from defects
in workmanship and material under normal use and proper maintenance for two
years (one year for adapters, attachments and cables) from original purchase. This
warranty shall not be effective if the product has been subject to overload, shock
load, misuse, negligence, accident or repairs attempted by others than Imada, Inc.
During the warranty period, we will, at our option, either repair or replace
defective products. Please call our customer service department for a return
authorization number and return the defective product to us with freight prepaid.
The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY, and we
hereby disclaim all other warranties, express, statutory or implied, applicable to the
products and/or software, including but not limited to all implied warranties of
merchantability, fitness, non-infringement, results, accuracy, security and freedom
from computer virus. In no event shall Imada, Inc. and/or its affiliated companies be
liable for any incidental, consequential or punitive damages in connection with the
use of its products and/or software.
3100 Dundee Rd., Suite 707, Northbrook, IL 60062 USA
Telephone: (847) 562-0834
Fax: (847) 562-0839
www.imada.com E-mail: imada@imada.com
ISO 9001 & ISO/IEC 17025 Accredited
Specifications subject to change without notice.
04/07
Complete color
catalog available.
Call 800-373-9989
or E-mail us.
Digital Force Gauge
Model: DS2
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Imada DS2

  • Page 1 2 YEAR WARRANTY (RESTRICTIONS APPLY) Imada, Inc. warrants its products to the original purchaser to be free from defects in workmanship and material under normal use and proper maintenance for two years (one year for adapters, attachments and cables) from original purchase. This warranty shall not be effective if the product has been subject to overload, shock load, misuse, negligence, accident or repairs attempted by others than Imada, Inc.
  • Page 2 For the most accurate results, use the gauge at temperatures close to ones on the certificate of calibration. 4. When mounting DS2 Series, use M4 mounting screws with a maximum insertion depth of 8 mm into the gauge. 5. Measure in line tension and compression forces only.
  • Page 3: Lcd Display

    2. Battery icon will flash when the gauge needs to be recharged. up to 110 lbf– #10-32 played.After 10 minutes, unit 3. Turn off power. Only use the IMADA AC adapter/charger pro- 220 lbf– powers down if no key is vided, AD120 for 115VAC, AD230 for 230VAC.
  • Page 4: General Operation

    Connect the CB-101 analog cable to the communications port and the device receiving the data. capacity, then zero with a measuring unit.To change to other units: 1. Turn off the gauge. DS2 Ranges (Resolution) Accuracy: ±0.2% F.S. ±1 LSD Model Capacity (Resolution) 2. Hold and press once.
  • Page 5: Communications Port

    COMMUNICATIONS PORT Hand Tighten Attachments Hand Tighten Attachments Port Pin Assignments Do not use tools to tighten attachments to the measuring shaft. Pin# Definition RS-232C and Digimatic Ground RS-232C Transmit Data Selecting Peak or Real time Measuring Mode Selecting Peak or Real Time Measuring Mode Analog Output ±1VDC Digimatic Data Request Press...
  • Page 6: Optional Settings

    OPTIONAL SETTINGS Selecting Test Type (continued from step 2) The following steps are not necessary for most test applications and may be skipped entirely. Select rapid data processing for Destructive Testing. Selecting High and Low Setpoints 3. After is pressed in step 2, the display briefly shows Program High and Low setpoints to enable GO/NG testing.

This manual is also suitable for:

Ds2-1

Table of Contents

Save PDF