Orban 424A Operating Manual page 27

Gated gompressoi/limrtei/de-esser
Table of Contents

Advertisement

g)
Measure
the
THD
at the
424A
output and
adjust
R26
(DISTORTION NULL)
to
minimize
it.
THD
should
not
exceed
0.03%
if
measured
using
a
20-20kHz
bandpass
filter
to
minimize
the effect of supersonic noise
upon
the
distortion
reading.
h)
Temporarily
reduce
the
oscillator
output
level
lOdB.
Set
the
424A
IDLE
GAIN
control
to
"0",
and
verify that the
424A
output
level
is
increased
lOdB
+_2dB.
Then
restore the
IDLE
GAIN
to "-I0".
i)
Disconnect
the oscillator
from
the
424A
input,
and connect
it
to
the wiper
of
R64
(OUTPUT
TRIM).
Set
the
oscillator
frequency
to
100Hz, and
adjust the
oscillator
output
level
until
a distorted
100Hz
feedthrough
component
can be
seen
on
the
scope monitoring
the
AC
VTVM.
Adjust
RI9
(THUMP
NULL)
to
minimize
the
amount
of
feedthrough.
j)
Disconnect
the oscillator
from
the wiper
of
R64.
Connect
the
DVM
to
the
output
of IC9B. Adjust
R28 (DE-ESSER
THUMP
NULL)
to
secure
a reading of
OVDC.
2)
Noise Test
a)
Suppress
the
oscillator
and
turn the
424A INPUT
ATTEN
to
"0".
Measure
the
noise
at
the
424A
output through
a
20-20kHz
bandpass
filter
with l8dB/oct
or
greater
slopes.
The
noise should not
exceed -68dBm.
NOTE:
If
this
specification
is
not
met, be
sure that
hum
or
RF
pickup
due
to
poor
test
equipment
configuration
or
grounding
is
not causing
falsely
high
readings.
3)
De-esser Operation
a)
Verify
that
the
de-esser
THRESHOLD
control
is
set
at
"less",
and
that
the
de-esser
OP/DEFEAT
switch
is
DEFEATED.
b)
Set the
oscillator
frequency
to
10kHz,
and
set
its
level
to
produce
+
1
2dBm
at the
424A
output.
c)
Switch
the
de-esser
OP/DEFEAT
switch
to
OP,
and
verify
that
the
424A
output
level
is
reduced
to
+6dBm,
+|dB.
d)
Verify
that
the
NORM
de-essing
lamp
is
ON.
Adjust
the
de-esser
THRESHOLD
control
clockwise,
and
verify
that
the
HEAVY
de-essing
lamp
comes
on
when
the control
is
set at
approximately
"4".
e)
Adjust
the
424A
de-esser
THRESHOLD
control
to
"more".
Switch
the
oscillator
frequency
to
3kHz, and
verify that
the
424A
output
level
becomes
+7.0dBm,
+ldB.
f)
Switch
the de-esser
OP/DEFEAT
switch
to
DEFEAT.
4)
Compressor/Limiter Operate
Mode
Tests
a)
Suppress
the
oscillator
output.
Verify
that
the
GATE THRESH
control
is
OFF
.
Switch
the
COMP/LIM OP/DEFEAT
switch
to
OP, and
verify that the
G/R
meter
recovers
to "0".
b)
Set the
oscillator
frequency
to
100Hz,
and advance
the
oscillator
output
level
until
the
424A
G/R
meter
reads
20dB G/R. Measure
the
THD
at
the
424A
output,
and
verify
that
it
is
less
than
0.03%. Observe
the
distortion
output
from
the
THD
analyzer on a scope,
and
verify that
the
distortion residual
looks
like
Fig.
D-l. Suppress
the
oscillator
output,
and
verify that the
time
required
for
the
G/R
meter
to
move
from 20dB
to
lOdB
G/R
is
2.0seconds,
+0.5seconds.
23