GB
Cat:II 2H 3+
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Triple-ring compact (TRC)
Triple-ring (TR)
Dual (DB) - inner crown
Dual (DB) - outer crown
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Triple-ring compact (TRC)
Triple-ring (TR)
Dual (DB) - inner crown only
Dual (DB) - outer crown only
Dual (DB) - inner & outer crown
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
30
GAS MAINTENANCE
TABLE FOR THE CHOICE OF THE INJECTORS
Nominal
Power
[kW]
1,00
1,75
3,00
3,50
3,80
0,80
3,40
G30/G31
28-30/37 mbar
Reduced
Ø injector
Power
[1/100 mm]
[kW]
0,40
50
0,45
66
0,75
87
1,50
92
1,50
98
0,40
46
1,50
65 (x2)
Air necessary for combustion [m
G20
20 mbar
Ø injector
[1/100 mm]
77
101
129
139
141
70
99 (x2)
/h x kW)
3
/h]
3
2,00
3,50
6,00
7,00
7,60
1,60
6,80
8,40