GAS CONNECTION
GB
II
Cat:
Installation to Natural Gas
Installation to Natural Gas must conform to the Code of Practice, etc.
The supply pressure for Natural Gas is 20 mbar.
The installation must conform to the relevant British/European Standards.
Installation to LP Gas
When operating on Butane gas a supply pressure of 28-30 mbar is required.
When using Propane gas a supply pressure of 37 mbar is required.
The installation must conform to the relevant British/European Standards.
Warning: Only a suitably qualified and registered installer, also with technical knowledge
of electricity should install the appliance.
He should observe the Regulations and Codes of Practice governing such installation of
gas appliances.
Note: We do not preclude connecting the appliance via a flexible hose; however it must
conform to BS669 or EN14800.
Notes:
Flexible hoses can be used where the sited ambient temperature of the hose
does not exceed 70°C. These hoses must be manufactured in accordance with
BS669 part 1 or EN 14800 and be of the correct construction for the type of gas
being used.
Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas
(LPG gas hoses can be identified by a either a red band or stripe on the rubber
outer coating of the hose).
The hose should not be crushed or trapped or be in contact with sharp or

abrasive edges.
IMPORTANT! It is the responsibility of the gas installer to ensure that the product is
fully tested and commisioned in accordance with current regulations to ensure there
are no gas escapes.