8.5.2.
CD Mechanism Error Code Table (CD Mechanism Unit (BRS11C))
Error Code
Diagnostic Contents
CD H15
CD Open Abnormal
CD H16
CD Closing Abnormal
F26
Communication between
CD servo LSI and micro-p
abnormal.
8.6.

Sales Demonstration Lock Function

8.6.1.
Entering into sales Demo Mode
Here is the procedures to enter into Sales Demonstration Lock.
Step 1: Turn on the unit.
Step 2: Select to any mode function.
Step 3: Press [
OPEN/CLOSE
Step 4: The display will show upon entering into this mode for 2 sec..
Note: [
] button is invalid and the main unit displays "LOCKED" while the lock function mode is entered.
OPEN/CLOSE
8.6.2.
Cancellation
Step 1: Turn on the unit.
Step 2: Select to any mode function.
Step 3: Press [
OPEN/CLOSE
Step 4: The display will show upon entering into this mode for 2 sec..
Description of error
During operation
POS_SW_R On fail to be
detected with 4 sec. Error
No. shall be clear by force
or during cold start.
During operation
POS_SW_CEN On fail to
be detected with 4 sec.
Error No. shall be clear by
force or during cold start.
During switch to CD func-
tion, if SENSE = "L" within
failsafe time of 20ms.
] key then [ / ] key at the same time,press and hold both [
] key then [ / ] key at the same time,press and hold both [
Automatic FL Display
23
Remarks
Press [ ] on main unit for
next error.
Press [ ] on main unit for
next error.
Press [ ] on main unit for
next error.
] and [ / ] keys for 5 sec.
OPEN/CLOSE
] and [ / ] keys for 5 sec.
OPEN/CLOSE

Advertisement