If required, the 16 basic settings (parameters) can be
adjusted.
Factory settings have a grey background.
Parameters marked with an * are described in more
detail below.
Par.
Setting
Meaning
Language setting
1
German
1
English
2
Danish
3
Swedish
4
Norwegian
5
Finnish
6
Preset time programs *
2
Week program 1
0
Week program 2 "Lunch break at home"
1
Week program 3 "Part-time work"
2
Backlight *
3
Deactivated
0
Activated
1
Summer/winter time changeover
4
No automatic changeover
0
Automatic changeover
1
Duration of the window function *
5
Window function not active
0
Valve opens at the latest after 30 minutes
30
...
...
Valve opens at the latest after 90 minutes
90
Sensitivity of the window function during
6
dropping room temperature *
0.2 (sensitive)
0.2
...
...
2.0 (less sensitive)
2.0
Factory setting:
Sensitivity of the window function during
7
rising room temperature *
0.1 (sensitive)
0.1
...
...
2.0 (less sensitive)
2.0
Factory setting:
Setting the valve stroke *
8
Standard valve stroke
0
Full-stroke mode
1
Temperature representation in the display
9
*
0
Set/programmed temperature
temperature)
Measured room temperature
1
"At home all day"
0.4
0.2
(setpoint
Par.
Setting
Meaning
Upper temperature limit
10
The room temperature cannot be set higher
16
than the specified upper temperature limit
17
(Max Limit).
...
Factory setting:
30
Lower temperature limit
11
The room temperature cannot be set lower
5
than the specified lower temperature limit
6
(Min Limit).
...
Factory setting:
15
Optimization function *
12
No optimization
0
Optimum start
1
Optimum start/stop
2
Temperature offset *
13
To adjust the temperatures measured by
3
the radiator controller and in the room
...
Factory setting:
-3
Battery type
14
Alkaline
0
Lithium
1
NiMH (accumulator chargeable)
2
Display valve position *
15
No display of the valve position
0
Momentary display of the valve position
1
Valve exercise day *
16
Monday
0
Tuesday
1
Wednesday
2
Thursday
3
Friday
4
Saturday
5
Sunday
6
Off
7
Window open function *
17
Off (no window function)
0
Auto
1
Cabled (with floating window contact)
2
Temperature unit
18
°Celsius
0
°Fahrenheit
1
Restore to factory setting
19
No reset
0
Reset only the basic settings
1
Reset only the time program
2
Reset all
3