Pre-Start Procedures; Cleaning And Maintenance; Draining Tank; Operation Instructions - Stanley DN 200-10-5 Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
There are no user serviceable parts inside this product
except those referred to in the manual. Always refer
servicing to qualified service personnel. Never remove
any part of the casing unless qualified to do so; this unit
contains dangerous voltages.
Warning!
For your protection if this product is to be used outdoors it
should not be exposed to rain or used in damp locations. Do
not place the product on damp surfaces, use a workbench
if available. For added protection use a suitable residual
current device (R.C.D.) at the socket outlet.
Note: If the mains cable requires replacing it must be
replaced with an identical one and fitted by a
qualified person.

5. PRE-START PROCEDURES

● Examine the machine for signs of transport damage.
Report any damage immediately to the company which
delivered the compressor.
● Verify that the tanks have been drained and are clear of
any moisture or dirt.
● The compressor should be set up near the working
consumer.
● Avoid long air lines and long supply lines (extensions).
● Make sure the intake air is dry and dust-free.
● Do not set up the compressor in damp or wet rooms.
● The compressor may only be used in suitable rooms
(with good ventilation and an ambient temperature from
+5°C to +40°C). There must be no dust, acids, vapours,
explosive gases or inflammable gases in the room.
● The compressor is designed to be used in dry rooms. It
is prohibited to use the compressor in areas where work
is conducted with sprayed water.

6. OPERATION INSTRUCTIONS

6.1 Start-Up Procedures
1. Verify that the On/Off switch is in the Off position.
2. Verify that the tank air pressure is at 0 PSI.
3. Attach the air hose to the discharge line.
4. Plug the unit into a properly grounded outlet.
5. Push the On/Off switch to On. The On/Off switch
will light-up to indicate the compressor is on. The
compressor will automatically cycle on and off to keep
the tank pressure maintained .
6. Adjust the pressure regulator to the proper pressure
setting required for the air tool.
6.2 Shut-Off Procedures
1. Push in the On/Off switch to the Off position.

7. CLEANING AND MAINTENANCE

Warning!
Pull the power plug before doing any cleaning and
maintenance work on the appliance.
Warning!
Wait until the compressor has completely cooled
down. Risk of burns!
Warning!
Always depressurize the tank before carrying out any
cleaning and maintenance work.
7.1 Cleaning
● Keep the safety devices free of dirt and dust as far
as possible. Wipe the equipment with a clean cloth or
blow it with compressed air at low pressure.
● We recommend that you clean the appliance
immediately after you use it.
● Clean the appliance regularly with a damp cloth
and some soft soap. Do not use cleaning agents or
solvents; these may be aggressive to the plastic parts
in the appliance. Ensure that no water can get into the
interior of the appliance.
● You must disconnect the hose and any spraying tools
from the compressor before cleaning. Do not clean the
compressor with water, solvents or the like.

7.2 Draining tank

The condensation water must be drained off each day
by opening the drain valve (ref. E) (on the bottom of the
pressure vessel).
1. Verify that the compressor is turned Off.
2. Holding the handle, tilt the compressor toward the
drain valve so that they are positioned at the bottom of
the tank.
3. Turn the drain valve to open the valve.
4. Keep the compressor tilted until all moisture has been
removed.
Warning!
The condensation water from the pressure vessel
will contain residual oil. Dispose of the condensation
water in an environmentally compatible manner at the
appropriate collection point.
7.3 Safety valve (ref. G)
The safety valve has been set for the highest permitted
pressure of the pressure vessel. It is prohibited to adjust
the safety valve or remove its seal. Actuate the safety valve
from time to time to ensure that it works when required.
Pull the ring with sufficient force (fig. 8) until you can hear
the compressed air being released. Then release the ring
again.
7.4 Storage
Warning!
Pull the mains plug out of the socket and ventilate the
appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
15
G
B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents