Dometic RM7405L Manual

Dometic RM7405L Manual

Absorption-refrigerator for caravan and motorhome

Advertisement

ABSORPTION - REFRIGERATOR for CARAVAN and MOTORHOME
RM 7271 L
RM 7275 L
RM 7291 L
RM 7295 L
RM 7361 L
RM 7365 L
RM 7401 L
RM 7405 L
EN
English
Type C40 / 110
822 6100 01
MANUAL
OPERATING INSTRUCTIONS
INSTALLATION INSTRUCTIONS
T.B. 06/2003

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM7405L

  • Page 1 MANUAL ABSORPTION - REFRIGERATOR for CARAVAN and MOTORHOME RM 7271 L RM 7275 L RM 7291 L RM 7295 L RM 7361 L RM 7365 L RM 7401 L RM 7405 L OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS English Type C40 / 110 822 6100 01 T.B.
  • Page 2 Asiakaspalvelu Kundservice These operating instructions should be kept in a safe place. If this device is passed on, please include these operating instructions with it. © Dometic GmbH - 2003 - Subject to change without notice - Printed in Germany...
  • Page 3: Table Of Contents

    INTRODUCTION FOR YOUR SAFETY Warning and safety notices Coolant WARRANTY AND CUSTOMER SERVICE Damages in transit DESCRIPTION OF MODEL REFRIGERATOR GUIDE Cleaning Using the refrigerator Storing food Making ice cubes Defrosting Positioning the storage racks Door locking Switching off the refrigerator Winter operation 5.10 Interior light 5.11 Changing the decor panel...
  • Page 4: Introduction

    1 1 . . 0 0 INTRODUCTION You have made an excellent choice in selecting the Dometic Absorption Refrigerator. We are sure that you will be fully satisfied with your new appliance in all respects. The appliance, which works silently, meets high quality standards and guarantees the efficient utilisation of resources and energy throughout its entire life cycle, during manufacture, in use and when being disposed of.
  • Page 5: Warranty And Customer

    Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the country concerned. For warranty or other servicing, please contact our Dometic Service department. Any damage due to impro- per use is not covered by the warranty. The warranty does not cover any modifica- tions to the appliance or the use of non-original Dometic parts;...
  • Page 6: Using The Refrigerator

    Using the refrigerator The cooling unit is silent in operation. Ÿ When the appliance is first put into operation, there may be a mild odour Ÿ which will disappear after a few hours. Ensure the living area is well ventilated. The refrigerator will take several hours to reach its operating temperature Ÿ...
  • Page 7: Electrical Operation

    A. Manual Energy Selection Electrical operation 5.2.2 1. 12V - operation (DC) The refrigerator should only be used while the motor is running, otherwise the on-board-battery would be discharged within a few hours! 1. Set energy selector switch 3. Use rotary switch (B) to regulate the (A) to 12V .
  • Page 8: Gas Operation

    (e.g. air in the gas pipe). 5. Briefly switch the refrigerator off and then on again using main switch (A). To remove air from the gas pipes, repeat this procedure 3-4 times. If these actions do not help, please call an authorised Dometic Service Centre.
  • Page 9 B. Automatic Energy Selection ( only with RM 7XX5 L ) 5.2.5 “AUTO”-operation RM7XX5 L - models are equipped with an “AUTO”-MATIC function. 1. Set energy selection switch (A) to position “AUTO” . The LED "AUTO" illuminates Manual operation is possible at any time. Explanations: Upon switching on, the electronics automatically select one of the three possible energy types: 230V - 12V - liquid gas.
  • Page 10 5. Briefly switch the refrigerator off and then on again using main switch (A). To remove air from the gas pipes, repeat this procedure 3-4 times. If these actions do not help, please call an authorised Dometic Service Centre. 5.2.7...
  • Page 11: Storing Food

    Storing food Always store food in sealed containers, aluminium foil or similar. Ÿ Never put hot food into the refrigerator, always let it cool down first. Ÿ Products that could emit volatile, flammable gases must not be stored in the Ÿ...
  • Page 12: Door Locking

    Door locking open close park-position / vent-position Switching off 1. Set energy selector switch (A) 2. Secure the door open by means of the door to position "0" (OFF). The stop. The door will be slightly ajar. This is to appliance is now fully switched prevent mould from forming inside off.
  • Page 13: Interior Light

    2. Detach defective light 3. Fit new light bulb bulb. Note: For 12V DC : 1 light bulb 12V, 2W Please contact Dometic Service Centres for 4. Clip the cover back in replacement light bulbs. place. 5.11 Changing the decor panel 3.
  • Page 14: Changing The Doorhang

    5.12 Changing the doorhang It is not always possible to change the door when the refrigerator is installed. 1. Open the door, 2. Take off the door by unscrew the hinge moving it upwards. screw and keep it to hand. 8.
  • Page 15: Troubleshooting

    5.13 Troubleshooting Before calling the authorised Service Department, please check whether: 1. The instructions in the section "Using the refrigerator" have been followed. 2. The refrigerator is not tilted excessiveley. 3. It is possible to operate the refrigerator with an available power source. Failure : The refrigerator does not work in gas operation mode.
  • Page 16: Maintenance

    5.15 Product liability Product liability of Dometic GmbH does not include damages which may arise from faulty operation, improper alterations or intervention in the equipment, adverse effects from the environment such as changes in temperature and air humidity, which may impact the equipment itself or the direct vicinity of the equipment or persons in the area.
  • Page 17: Technical Data

    5.19 Technical data Model Dimensions Groos capacity Usable Connection * Consumption Netweight Ignition Stepped- H x W x D (mm) incl. freezer capacity of Mains / Battery electricity / gas Flame cabinet depth incl. door compartment freezer in 24 hrs Failure compartment Device...
  • Page 18: Declaration Of Conformity

    5.20 Declaration of conformity...
  • Page 19: Installation Guide

    In some OEM appli- cations it may not be possible for these instructions to be followed exactly. In this case an authorised Dometic representative may issue supplementary instruction In Europe, for example, gas appliances, cable laying, installation of gas cylinders, as well as approval and checking for leaks must comply with EN 1949 for liquid gas units in vehicles.
  • Page 20: Draught-Free Installation

    The refrigerator must be sealed in accordance with EN 1949. Illustrated below are two typical approved methods of sealing. Proposal 1: Using the Installation Sealing Kit from Dometic FIG. 1 (SP.No. 241 2559-00, available from Dometic) Insert lipped seals (A) into the installation recesses at the bottom and at each side.
  • Page 21: Ventilation And Air Extraction

    13cm² (EN1949). The ventilation grilles must have an open cross-section of at least 250 cm2. This is reached using the Dometic Absorber Ventilation and Air Extraction System L100 / L 200 that has been tested and approved for this purpose.
  • Page 22: Installation Of The Ventilation System

    Installing the ventilation system L 200 L 100 To install the ventilation grilles, cut two rectangles (451mm x 156mm) in the outer wall of the vehicle (for position of the cuts, see point 6.3). Item 1 does not apply for installation framess with an integrated seal.
  • Page 23: Installation Recess

    Installation recess The refrigerator must be installed draught-free in a recess. The measurements of the recess are given in the table below. Step (A) is only required for cabinets with a step. Push the appliance far enough into the recess until the front edge of the refrigerator casing is flush with the front of the recess.
  • Page 24: Fume Extraction

    Fume extraction Fume extraction must be arranged in such a way as to provide complete extraction of all products of combustion to an area outside the living area. The flue system must slope in an upward direction in order to avoid a build-up of condensation.
  • Page 25: Gas Installation

    6.7.2 Separate fume extraction ( special accessories ) min. 10 mm max. 20 mm Cutout: 80mm high 40mm wide 1. Cut an 80mm x 40mm rectangle in the outer wall of the caravan. The position of the cut must be appropriate to the particular model of refrigerator and installation conditions.
  • Page 26 The gas connection to the appliance is effected by means of a suitable Ÿ Ÿ coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto). The gas connection may only be carried out by a qualified personnel. Following proper installation, a testing for leakage and a flame test must be car- ried out by *qualified personnel in compliance with EN 1949 .
  • Page 27: Electrical Installation

    The power cable must be laid in such a way that it does not come in contact with hot components of the unit/burner or with sharp edges. If the connection cable is damaged it must be replaced by the Customer Service at Dometic, or by respectively qualified personnel, in order to prevent any hazards. Battery connection 6.9.2...
  • Page 28 From the manual energy mode to the automatic energy mode For all RM 7XX1 appliances (MES) there is an additional possibility for retrofitting to an RM 7XX5 device with AES functions. Please consult your nearest Dometic Customer Service or your specialist dealer.
  • Page 29: Wiring Diagram

    6.9.6 Wiring diagram Wiring diagram for RM 7XX1 L - models and RM 7XX5 L - models ignition unit Connections: ionisation A = Ground heating element DC plug B = Plus heating element DC C = Ground electronics ignition D = Plus electronics plug Reed contacts (sensor switching)
  • Page 30 Dometic GmbH In der Steinwiese 16 D-57074 Siegen www.dometic.de/caravan www.dometic.com...