KX-TC1868B / KX-TC1871B / KX-TC1872B
9.3.
Adjustment X101
IN case of SS system, Carrier signal frequency directly by Frequency counter, can not be measured because sending signal is
spread by PN code.
So, the confirmation and adjustment is made under the Continuous Send mode of TEST MODE.
Adjust the TX carrier(CW) frequency on the RF unit.
Equipment: Frequency counter
TP for adjustment: TP_ANT
Adjustment point: VC101 (RF unit)
Adjustment range: 906.000 ± 0.002 MHz (1ch)
9.4.
Base Unit Reference Drawing
(COMPONENT VIEW)
TEST
1ch
10ch
VC101
38
ANT GND
ANT
Line A
Line B