5.5.2
How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
By activation of the 'Reset error buffer' command in the
SAM menu.
When you transmit the code 0 6 2 5 9 9 with a standard
remote control transmitter.
5.5.3
Error Codes
Table 5-1 Error code overview
Error
Device
1
TEA6422D
2
MSP3451G
3
PCF8574-SCAVIO
4
PCF8591
5
FS6377
6
PCF8574-PSU
7
24C16 OTC
8
24C16 PW
9
SAA7118
10
AD9887
11
SDA9400
12
EP1K30QC
13
PDP
20
Download comm.
21
CSP comm.
30
PDP
40
Temperature alarm
70
Vs overvoltage
71
Vs undervoltage
72
Va undervoltage
73
+5V undervoltage
74
+3V3 undervoltage
75
DC-PROT
76
TEMP-PSU
77
Protection with reason unknown
78
Protection after several retries
9x
OTC
Notes:
In case of non-intermittent faults, clear the error buffer
before you begin the repair. This to ensure that old error
codes are no longer present.
If possible, check the entire contents of the error buffer. In
some situations, an error code is only the result of another
error code and not the actual cause (e.g., a fault in the
protection detection circuitry can also lead to a protection).
5.6

The Blinking LED Procedure

Via this procedure, you can make the contents of the error
buffer visible via the front LED (orange colour).This is
especially useful when there is no picture. When no errors are
present, the LED will stay green.
When the SDM is entered, or when code 0 6 2 5 0 0 is entered
with the remote control, the LED will blink the contents of the
error-buffer.
Service Modes, Error Codes and Fault Finding
Description
Audio switch (only Enhanced)
Sound processor
I/O expander SCAVIO
AD-DA expander
Clock generator
I/O expander PSU
NVM OTC
NVM PW
Video decoder (only Enhanced)
ADC/TMDS receiver
De-interlacer (only Enhanced)
EPLD processor
I2C error of the PDP
Errors during downloading
CSP time-out error
Display HW error
Detection of over-temperature
Overvoltage on Vs, Va, +3V3, +5V or a combination
Undervoltage on Vs
Undervoltage on Va
Undervoltage on +5V
Undervoltage on +3V3
Audio amplifier protection
Over-temperature in PSU
No valid protection can be read, but protection is active (PSU)
PW Scaler will not start comm. with OTC after several retries.
Internal OTC error. Replace.
Digitized in Heiloo, Holland
FM24
Error-codes ≥ 10 are shown as follows:
1. n long blinks of 750 ms, which is/are an indication of the
decimal digit,
2. a pause of 1.5 s,
3. n short blinks (n = 1-9),
4. when all the error-codes are displayed, the sequence
finishes with a LED blink of 3 s,
5. the sequence starts again.
Example of error buffer: 12 9 6 0 0
After entering SDM:
1. 1 long blink of 750 ms followed by a pause of 1.5 s,
2. 2 short blinks followed by a pause of 3 s,
3. 9 short blinks followed by a pause of 3 s,
4. 6 short blinks followed by a pause of 3 s,
5. 1 long blink of 3 s to finish the sequence,
6. the sequence starts again.
31/8/2014
5.
EN 21
Item
Dia-
gr.
7798
SC13
7812
SC14
7540
SC8
7530
SC8
7570
SC9
7370
P3
7430
SC7
7580
SC9
7225
SC5
7170
SC4
7280
SC5
7656
SC11
7341
P3
7308A/B
P3
7308C/D
P3
7330A/B
P3
7330C/D
P3
7362
P3
7366A
P3
7383