Saturation Display; Audible Signal; Cleaning And Maintenance - Siemens LC91KB572 Instruction Manual

Extractor hood
Table of Contents

Advertisement

Saturation display

When the metal grease filters or the activated charcoal filter
are/is saturated, a signal sounds for approx. four seconds after
the fan is switched off.
The corresponding symbols appear in the display panel:
!
Metal grease filter:
Activated charcoal filter:
If you have not yet done so, carry out the following steps now:
Clean the metal grease filters or replace the activated
charcoal filters; see section Cleaning and maintenance or the
"CleanAir air recirculation module" printed supplement.
Reset the saturation indicator; see section Cleaning and
maintenance.
Resetting the saturation indicator
Press and hold the - button until the saturation indicator no
longer flashes.
The saturation indicator is reset.
Switching over the display for circulating-air mode
For the air circulation mode, the electronic control display must
be switched over according to the accessory used:
Starter set for circulating-air mode
Check whether the extractor hood is connected and switched
1.
off.
Press and hold the
and
#
2.
lights up in the display panel.
™"
The electronic control is switched over to the starter set for air
recirculation.

Cleaning and maintenance

:
Risk of burns!
The appliance will become hot during operation, especially
near the bulbs. Allow the appliance to cool down before
cleaning.
:
Risk of electric shock!
Penetrating moisture may result in an electric shock. Clean the
appliance using a damp cloth only. Before cleaning, pull out the
mains plug or switch off the circuit breaker in the fuse box.
:
Risk of electric shock!
Do not use any high-pressure cleaners or steam cleaners,
which can result in an electric shock.
:
Risk of injury!
Components inside the appliance may have sharp edges. Wear
protective gloves.
Cleaning agents
Observe the information in the table to ensure that the different
surfaces are not damaged by using the wrong type of cleaning
agent. Do not use
harsh or abrasive cleaning agents,
cleaning agents with a high concentration of alcohol,
hard scouring pads or sponges,
high-pressure cleaners or steam cleaners.
Wash new sponge cloths thoroughly before use.
Follow all instructions and warnings included with the cleaning
agents.
"
buttons at the same time until
z
CleanAir air recirculation module
Check whether the extractor hood is connected and switched
1.
off.
Press and hold the
and
#
2.
lights up in the display panel.
™"
Release the
and
buttons and then press and hold them
#
z
3.
again at the same time until
panel.
The electronic control is switched over to the CleanAir air
recirculation module for air recirculation.
Switching over the display for exhaust air mode
Check whether the extractor hood is connected and switched
1.
off.
Press the
#
and
z
buttons at the same time until
2.
up in the display panel.
The electronic control is switched over to air extraction.

Audible signal

Switching on
Switch off the fan.
1.
Press and hold the
#
and + buttons until an audible signal
2.
sounds.
The audible signal is switched on.
Switching off
Switch off the fan.
1.
Press and hold the
and + buttons until an audible signal
#
2.
sounds.
The audible signal is switched off.
Area
Cleaning agents
Stainless steel
Hot soapy water:
Clean with a dish cloth and dry with a
soft cloth.
Clean stainless steel surfaces in the
direction of the grain only.
Special stainless steel cleaning prod-
ucts are available from our after-sales
service or from specialist retailers.
Apply a very thin layer of the cleaning
product with a soft cloth.
Painted surfaces
Hot soapy water:
Clean using a damp dish cloth and dry
with a soft cloth/towel.
Do not use any stainless steel cleaners.
Aluminium and plas-
Glass cleaner:
tic
Clean with a soft cloth.
Glass
Glass cleaner:
Clean with a soft cloth. Do not use a
glass scraper.
Operating controls
Hot soapy water:
Clean using a damp dish cloth and dry
with a soft cloth.
Risk of damage to the electronics from
penetrating moisture. Never clean oper-
ator controls with a wet cloth.
Do not use any stainless steel cleaners.
buttons at the same time until
z
lights up in the display
'"
!
lights
7