All refrigerators are equipped with 2 stickers for each single lid. The stickers must be applied as
showed in the pictures:
Before switching on the machine, it is necessary to clean it as indicated in the "Cleaning" paragraph.
Always comply with the provisions of the local authorities in charge regarding the cleaning
of the machine.
Daily clean and sanitize the machine.
The appliance must not be cleaned by a water jet.
Switch off the main switch and disconnect the power plug (pic. 7 in appendix-88) before
starting any operation.
Use a solution of cold water and sodium hypochlorite (bleach) with a 10 grams (1/2 spoon)
for 1 liter of water ratio. Rinse with lukewarm water.
A greater quantity of beach could damage the material of the auger.
If the plastic parts are washed in the dishwashing machine, verify that the temperature is
not higher than 60°C or 140°F, because they could be damaged.
Do not use any abrasive powder.
Cleaning is very important for the life and maintenance of the machine; we recommend to periodically
clean the parts that are in contact with the product using the following procedure.
See the picture at the end of this manual.
Empty the tanks by opening the outlets and blocking them (pic. 8 in appendix-88), moving the little
letter from the left to the right.
Remove the lamp (pic. 9 in appendix-88), pour water in the tanks and then empty them.
Remove the auger ring nut (pic. 10 and 11 in appendix-88).
Remove the tank unscrewing the hooks grips (pic. 12 in appendix-88), if present, and opening the
hooks (pic. 13 in appendix-88); lift the tank as shown in pic. 14 and 15 in appendix-88.
Unscrew the ring nut (pic. 16 in appendix-88) in order to remove the vertical auger (pic. 17 in
appendix-88).