  • Page 1 USB to RS-422 / 485 XC4132 USB To Serial Operation Manual First Edition, Jun 2008...
  • Page 2: Table Of Contents

    …………………… 6 Product Views ………………………………………………… 6 USB Type A Connector ……………………………………… Serial I/O Port of RS-422/485 …………………..…………… Terminator …………………………………………………… LED Indicators ……………………………………………… 5. XC4132 Driver installation ……………………… Driver Installation …………………………………………… 6. Hardware Installation & Setup ……………………… Hardware installation ………………………………………… Hardware setup …………………………………………………...
  • Page 3: Introduction

    US-101-485 compatible with fully compatible the USB V1.0~ 2.0. XC4132 electrical power from USB port and doesn't need any power adapter. You can connect a PC USB port or USB hub to XC4132 via the USB cable and High-Speed RS-485/422 serial port which features easy connectivity for traditional serial devices in your working environments.
  • Page 4: Package Checklist

    Package checklist XC4132 product shipped with the following items: n 1 unit of XC4132 USB to RS-485/422 converter n 1 unit of A type to A type USB cable n User Operation Manual of software CD NOTE: Please notify your sales representative if any of the above items is...
  • Page 5: Product Specification

    Product Specification l Serial Port l RS-485/422 ● No. of Ports : 422/485 x 1 Port (Terminal Block) ● RS-422 Signals : RxD+ , RxD- , TxD+ , TxD- in Full-duplex (Surge Protection) ● RS-485 Signals : Data+ , Data- in Half-duplex (Surge Protection) ●...
  • Page 6 l Driver OS Support ● Windows – 98E / 2000 / XP / Server 2003 /Vista , Mac Osx / Os9 , Linux 2.4 / 2.6 l Power :USB bus power as voltage DC +5V l Environment : ● Operating Temperature: 0℃〜60℃ ●...
  • Page 7: Product Panel Views Description

    Terminator USB Type A Connector Power Outlet - The XC4132 USB to RS-485/422 powered by USB (Universal Serial Bus) port, a single 5V DC (Inner positive/outer negative) power supply, and 500mA of current. Connect to the USB cable between PC USB port or USB hub and XC4132 USB port.
  • Page 8: Serial I/O Port Of Rs-422/485

    XC4132 USB port is USB type A connector and it is fully compatible with the USB V1.1~2.0 Serial I/O Port Serial I/O Port of RS-485/422 To connected the serial data cable between the converter and the serial device. Please follow the parameter setup procedures to configure the converter (see the following chapters).
  • Page 9: Led Indicators

    LED Indicators Power LED SYS (Red): It is power indicator (When power on, the SYS LED will be on.)
  • Page 10: Xc4132 Driver Installation

    XC4132 Driver Installation When setting up XC4132 adapter for the first time, you have to install CP210x as “XC4132 Driver” first in your computer device before connecting. There are several kinds OS such as Windows 98 / XP / 2000 / VISTA…, Linux …, Mac…., etc.
  • Page 11 B. Choose “Next” Icon If your computer equipment is running Windows OS that the pop-up screen of installing massage will be showed as “CP210x VCP Drivers for Windows 2000/XP on your computer” and then to Click “Next” icon for going to next step. C.
  • Page 12 D. Choose destination location It is for saving the CP210x driver software in destination location of computer. E. Execute the program installation Click the “install” icon to begin installation of CP210x driver.
  • Page 13 F. install CP210x VCP Driver for Windows 2000/XP After click “Install” icon, the install shield wizard is installing Silicon Laboratories CP210x drivers for Windows 2000/XP and installation location. G. Install Shield Wizard Complete CP210x VCP driver has successfully installed and click “Finish” icon for exiting the wizard.
  • Page 14: Hardware Installation & Setup

    2. USB cable of type A has two distinct connectors to connect the cable from USB device as on computer or USB hub. 3. Connect USB cable between PC USB port or USB hub and XC4132 adapter. 4. Connect the serial port RS-485/422 equipments to XC4132 of USB to serial...
  • Page 15 5. After connecting XC4132 USB to serial converter, a massage as “ New device has been connected” will pop-up on screen. However, the CT210x VCP driver needs to be installed on PC in advance. 6. The SYS indicator of red LED will be turned on. The XC4132 USB to serial adapter is active.
  • Page 16: Hardware Setup

    Hardware Setup When XC4132 adapter has been successfully connected and you can setup more detail parameters by computer management. A. Into “Manage” icon in My Computer Click “My Computer” icon and then press the right side button of mouse. After you click the manage item on list bar then “Computer...
  • Page 17 B. Choose “Device Manager” and click “Ports (COM & LPT)” in Device Manager Click “Device Manager” item, all devices of computer will be list on right site of screen and then click “Ports (COM & LPT) item to look for more COM devices.
  • Page 18 D. Device general status of CP210x USB to UART Bridge Controller This shows the status of device and general product information. COM port number of device also display on. E. “Port Settings” communication detail information This is for checking and setting more detail parameters of device for communication.
  • Page 19 F. “Driver” detail information The driver detail information as you installed in your computer. G. “Details” item It is for checking device ID numbers as device instance ID.
  • Page 20: Appendix A - Pin Outs And Cable Wiring

    RS-422 : PIN 1 : T+ PIN 2 : T- PIN 3 : R+ PIN 4 : R- RS-485 : PIN 1 : D+ PIN 2 : D- □ □ RS-422 Wiring Diagram □ Serial Device XC4132 2 T- 1 T+ 4 R- 3 R+...
  • Page 21: Rs-422 Wiring Diagram

    □ □ RS-485 Wiring Diagram □ Serial Device XC4132 2 D- 1 D+...