Page 1
Training Manual : ALVA Indoor Gas Heaters SPECIFICATIONS Model ALVA GH302 Description Infrared Heater Type of Gas Operating pressure2 .8kPa Injector size 0.59 Gas Consumption Position 3 (3 panels) 265gr/hr Position 2 (2 panels) 175gr/hr Position 1 (1 panel) 90gr/hr Heat output 4.2kW...
Contact Details: 086 100 (ALVA) 2582 e-mail: info@stingray.co.za Features & Benefits Of Owning An ALVA Gas Heater: * LPGSASA Approved * Oxygen Depletion System (ODS) Safety Feature Shuts * Safe & Easy To Use Heater Down If Carbon * Spares Readily Available...
Users are no longer allowed to purge the excess gas themselves. GAS CYLINDER: A 9kg ALVA gas cylinder with a 5/8 inch BSP left hand thread is recommended. This matches the supplied regulator.
Heater Set Up: This heater makes use of an industrial cylinder (9kg cylinder recommended) with a 5/8” BSP thread; horizontal exit valve. The Bullnose regulator supplied with the heater tightens to the left hand side (anti-clockwise). (Figure A) If you have bought a new gas cylinder, the cylinder needs to be purged (cleared out), before it’s first use.
Tighten the connection and retry the leak test. If you are unsure or if you cannot tighten the connection, place the cylinder outside in a cool, well-ventilated area and contact ALVA on 086 100 (ALVA) 2582. Connections to be leak tested...
Using The Heater: This heater can be regulated to three different heat selections: “ LOW” “ MED” “ HIGH” Open the cylinder valve by turning the cylinder valve to the left. Press the control knob down at the “ OFF” position.
The heater should be checked once a year by a qualified technician. GOOD If faults are suspected or detected, stop using the heater and contact ALVA. Clean the exterior and storage area of the heater when required to remove dust and prevent lint build Not enough air DO NOT use abrasive products to clean the heater;...
Page 8
If they are unable to successfully solve the problem telephonically, the customers details are taken and a highly trained ALVA technician is despatched to their premises. If the problem is covered under the warranty for that product, then there is no cost to the client for the callout and repair work.
Need help?
Do you have a question about the GH313 and is the answer not in the manual?
Questions and answers