Allied Air A80UH1E Installation Instructions Manual page 22

Warm air gas furnace upflow / horizontal left and right air discharge
Table of Contents

Advertisement

Before connecting the thermostat, check to make sure the
wires will be long enough for servicing at a later date. Make
sure that thermostat wire is long enough to facilitate future
removal of blower for service.
Complete the wiring connections to the equipment. Use the
provided unit wiring diagram and the field wiring diagram
shown in Figure 33. Use 18 gauge wire or larger that is
suitable for Class II rating for thermostat connections.
Electrically ground the unit according to local codes or, in the
absence of local codes, according to the current National
Electric Code (ANSI/NFPA No. 70). A green ground wire is
provided in the field make-up box.
NOTE: This furnace contains electronic components that
are polarity sensitive. Make sure that the furnace is wired
correctly and is properly grounded.
Accessory Terminals
One line voltage "EAC" 1/4" spade terminal is provided on
the furnace integrated control. See figure 34 for integrated
control configuration. This terminal is energized when the
indoor blower is operating. Any accessory rated up to one
amp can be connected to this terminal with the neutral leg
of the circuit being connected to one of the provided neutral
terminals. If an accessory rated at greater than one amp is
connected to this terminal, it is necessary to use an external
relay.
One line voltage "HUM" 1/4" spade terminal is provided on
the furnace integrated control. See Figure 34 for integrated
control configuration. This terminal is energized in the
heating mode when the combustion air inducer is operating.
Any humidifier rated up to one amp can be connected to this
terminal with the neutral leg of the circuit being connected to
one of the provided neutral terminals. If a humidifier rated
at greater than one amp is connected to this terminal, it is
necessary to use an external relay relay.
One 24V "H" 1/4" spade terminal is provided on the furnace
control board. Any humidifier rated up to 0.5 amp can be
connected to this terminal with the ground leg of the circuit
connected to ground or the "C" terminal. See Figure 34 for
control board configuration. This terminal is energized in the
heating mode when the combustion air inducer is operating.
Page 22 of 34
Generator Use - Voltage Requirements
The following requirements must be kept in mind when
specifying a generator for use with this equipment:
The furnace requires 120 volts ± 10% (Range: 108 volts
to 132 volts).
The furnace operates at 60 Hz ± 5% (Range: 57 Hz to
63 Hz).
The furnace integrated control requires both polarity
and proper ground. Both polarity and proper grounding
should be checked before attempting to operate the
furnace on either permanent or temporary power.
Generator should have a wave form distortion of less
than 5% RHO.
Thermostat
Install the room thermostat according to the instructions
provided with the thermostat. See Figure 31 for thermostat
designations. If the furnace is being matched with a
heat pump, refer to the FM21 installation instruction or
appropriate dual fuel thermostat instructions.
Condensing Unit Thermostat Designations
(Refer to Specific Thermostat and Outdoor Unit.)
* Note: "R" Required on some outdoor units.
Indoor Blower Speeds
1. When the thermostat is set to "FAN ON," the indoor
blower will run continuously on the fan speed when
there is no cooling or heating demand.
2. When the unit is running in the heating mode, the indoor
blower will run on the heating speed.
3. When there is a cooling demand, the indoor blower will
run on the cooling speed.
Issue 1624
Figure 31
507330-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

80g1uhe

Table of Contents