After Pressing The Key F2; Sp Parameter - A-S-S BASS 2020 Working Instructions

Automatic single head serging unit for sewing of front- and back trouses without knee lining

Advertisement

e.g. GP: 01 = 0.5 sec
ERROR TIME ANF
The functional key F3 is used to select the parameters in the list or basic
settings. Through pressuring on the key the parameter number increases
accordingly .By pressing function key F4 the parameter number decreases
once more.
Pressuring on the function key F2 the Curser flashes on the first position that
can be changed, after renewed pressing of the key F2, the Cursor moves a
step to the right. Now the numerical values can be increased or reduced with
the help of the keys F3 and F4.
If you press the key P/ once more, the program is shown again.

3 After pressing the key F2

The special parameters appear in the display which when changed will a have
an effect on the joint program selected currently. This is applies only to the
stitch number 4 (inseam) and the join number 5 (outseam) in the preseam's
1,2,3 only the sewing speed can be altered.

SP Parameter

01 = SLOW SEW. SPEED
02 = FAST SEW. SPEED
03 = SLOW SEW. DURATIO
04 = CONT. GUIDE DOWN
05 = UNLOADER MOVES
06 = TILL TABLE BLOW
07 = TABLE BLOW DURAT
08 = TILL UNLOADER
09 = Free
10 = START MODUS
11 = TILL CONT. ROLLER
12 = CONT. ROLLER DOWN
13 = CONT. ROLLER UP
14 = CHAIN STOP DURAT
15 = STACKER MODUS
16 = Free
e. g. VP: 03 = 5000 RPM
1. SEWINGSPEED
(xx00Rpm)
(xx00Rpm)
(01cm)
(01cm)
(01cm)
(01cm)
(01cm)
(0.01 sec)
(01cm)
(01cm)
(01cm)
(01cm)
(01cm)
(01cm)
(01)
(01cm)
3