LED INDICATIONS

3.1
Lynx Ion + Shunt LED indications
Firmware version 1.22 and higher.
Status LED state
Off
Blinking fast
On
Blinking
Flashing/beeping 1 time
Flashing/beeping 2 times
Flashing/beeping 3 times
Flashing/beeping 4 times
Flashing/beeping 5 times
Flashing/beeping 6 times
Flashing/beeping 7 times
Flashing/beeping 8 times
Flashing/beeping 9 times
Flashing/beeping 10 times
Flashing/beeping 11 times
Flashing/beeping 12 times
Flashing/beeping 13 times
Flashing/beeping 14 times
Flashing/beeping 15 times
Flashing/beeping 16 times
Flashing/beeping 17 times
Blinking/beeping fast
Flashing 3 times (no beeping)
Flashing/beeping 18 times
Flashing/beeping 19 times
Flashing 2 times (no beeping)
Description
System is in standby mode. Press START button to start
up the system
Initialization.
Running
Balancing active
Battery initialization error
No batteries connected
Unknown battery connected / battery connected to a
running system.
Different types of batteries connected
Number of connected batteries incorrect
Shunt fault
Battery measure error occurred
Internal calculation error
Number of batteries in series incorrect
Number of batteries incorrect (only used when using
static number of battery configuration)
Not used
Not used
Over voltage
Under voltage
Over temperature
Under temperature
ADC data error
Battery BMS error (slave)
Battery BMS warning (slave)
Pre-Charge error
Safety contactor error
Over current error on External status or external safety
contactor output (appendix A connector B)

Advertisement