SUB450
SUB450 Amplifier
LINE VOLTAGE
US 120vac/60Hz
Asia 100vac/50Hz
Parameter
Amp Section
Type (Class AB, D, other)
Load Impedance (speaker)
Rated Output Power
THD@ Rated Power
THD @ 1 Watt
DC Offset
Damping factor
Input Sensitivity
Input Frequency
Line Input (L&R)
LFE Input
Speaker/Hi Level Input
Signal to Noise
SNR-A-Weighted
SNR-unweighted
SNR @ 1W-unweighted
Residual Noise Floor
Residual Noise Floor
Input Impedance
Line input L&R , LFE
Speaker/Hi Level Input
Filters
Low Pass (fixed or variable)
Slope & Q
Subsonic filter (HPF)
Slope & Q
Limiter (yes/no)
Features
LFE Input
Volume pot Taper (lin/log)
ATO
Input Configuration
Line In (L,R)
Line level in LFE
Spkr/Hi Level In
(L,R)
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
ATO Input Frequency
ATO Level
ATO Turn-on time
Auto Mute/ Turn-OFF Time
Power on Delay time
Transients/Pops
ATO Transient
Turn-on Transient
Turn-off Transient
Efficiency
Stand-by Input Power
Power Cons.@rated power
Protection
Short Circuit Protection
Thermal Protection
DC Offset Protection
Line Fuse Rating
100W Powered Sub/ Plate Amp
Yes/No
Hi/Lo Line
Yes
108-132
Vrms
Yes
90-110
Vrms
Specification
Unit
AB AB
4 Ohms
100 Watts
0.08 %
0.1 %
10 mV-DC
>100 DF
50 Hz
250 mVrms
135 mVrms
2.5 Vrms
100 dBA
80 dBr
60 dBr
1.5 mVrms
1
mVrms(max)
>15 K ohms
4.7 K ohms
fixed
--
dB/Octave
Hz
dB/Octave
YES
--
YES
log
--
YES
L ,R
--
LFE
L,R
--
YES
--
50 Hz
2 mV
5 ms
15 minutes
3 sec.
5 mV-peak
50 mV-peak
50 mV-peak
13 Watts
185 Watts
YES
--
65 deg. C
--
YES
--
2.5 Amps
Unit
Notes
Normal Operation
Normal Operation
QA Test
Limits
Conditions
n/a
n/a
Nominal
95
1 input driven
0.3
22k filter
0.5
22k filter
20
@ Speaker Outputs
50
50
Nominal Freq.
±2dB
To Rated Power
±2dB
To Rated Power
±2dB
To Rated Power
90
rel. to rated power
75
rel. to rated power
55
rel. to 1W Output
Volume @max, using RMS reading
2.5
DMM/VOM (or A/P)
Volume @max, w/ A/P Swept Bandpass
2
Measurement (Line freq.+ harmonics)
n/a
Nominal
n/a
Nominal
±2dB
n/a
±2dB
n/a
n/a
functional
functional
functional
functional
functional
functional
functional
functional
@50
to
e
functional
driven
functional
AC on, signal applied
functional
T before muting, after signal is removed
functional
AC Power Applied
10
@ Speaker Outputs
100
@ Speaker Outputs
100
@ Speaker Outputs
15
@ nom. line voltage
195
@ nom. line voltage
functional
Direct short at output
functional
@1/8 max unclipped Power
functional
DC present at Speaker Out leads
2.5
Type-T or Slo Blo
2
Notes
External Sink required for Class AB
Z-curve required
Measured at speaker terminals, Output
power 90 Watts THD 0.1 %
1 input driven
1 input driven
LFE input driven only
(-20 dB below Line In)...1 input driven
A-Weighting filter
22k filter
22k filter
BW Limited to 500 Hz
RCA inputs: L , R Summed to Mono
L R Summed to Mono
put /
c
Auto turn of time (T) must be 10 > T <15
AC Line cycled from OFF to ON
AC Line cycled from ON to OFF
Maximum allowable input power.
100 Watts @ 4 Ohms nominal line voltage
rise
Relay or crowbar (for driver/fire protection)
External fuse with UL/SEMKO rated holder
Need help?
Do you have a question about the SUB450 and is the answer not in the manual?