Parts List-3
SYMBOL
PARTS NO.
015 RP-376
019 4TSH-19#2
022 TT-311-UR
034 SEL1124R
069 C-4629A01
072 C-4620A01
Adjustment
Instruments : DC milli–voltmeter
Notes
: Prior to Bias Adjustment, run about 5minutes with rated output(8ohms) and
warm up Power Transistor and Heat Sink. Set input off.
Step
1
X-1289-01 PCB R639
2
X-1289-01 PCB R640

Case Outlines

2SC536K
2SA1345
2SC3399
2SA1376A
2SC3478A
2SC3708
DESCRIPTION
PRINTED REAR CHASSIS
PLASTIC FOOT
POWER TRANSFORMER
LED
AC INLET
AC CORD SET for STD
Coupling
NJM7805FA
TC74HC595AP
NJM2114D
OPA2604AP
SYMBOL
072 C-4622A01
072 C-4623A01
072 C-4624A01
081 SZ4-21A00
081 TZ-183
092 RR-A91
Location
X-1289-03 PCB VR601
X-1289-02 PCB VR602
2SB631K
2SD600K
2SC3902
2SA1507
LB1641
4
PARTS NO.
DESCRIPTION
AC CORD SET for AUSTRALIA
AC CORD SET for UK
AC CORD SET for CEE
INSIDE CARTON
STYROL MOULDING
REMOTE UNIT
Adjust for
DC milli–voltmeter reads 5mV
TMP47C400BN-1
2SB817
2SD1047