Battery Indicator; Conserving Battery Power - Panasonic CF-25 Operating Instructions Manual

Table of Contents

Advertisement

Battery Indicator

Battery Indicator
Orange
Charging
Green
Fully charged
Power low
Suspend (hibernation) function is enabled:
- The beeper sounds at the same time.
- The computer automatically enters the hibernation
Red
mode approximately 4 minutes after the beeper
sounds.
Suspend (hibernation) function is disabled:
- The beeper sounds approximately 7 minutes later.
- The computer automatically turns off several min-
utes after the beeper sounds.
The battery or AC adapter may not have been
Blinking red
connected properly.
Blinking orange
Refreshing
Refreshing required
Blinking green
Blinking orange
The temperature is outside the range of approximately
for 5 seconds after
5°C to 35°C (41°F to 95°F).
the AC adapter is
connected.

Conserving Battery Power

"Power management" conserves battery power and enables the computer to be oper-
ated to the maximum extent possible. To run this program, select Wset25 in Win-
dows or Setup25 in DOS.
Battery Status
The computer enters the standby mode immediately after
In this mode, the HDD motor, CPU* and LCD backlight are turned off.
*Only when Windows is running.
It is recommended that the battery is installed when using the computer.
In the setup program, set "Power Saving" in "Power Management" to "Advanced".
NOTE
Certain applications may not run when "Power Saving" is set to "Advanced". If this is the
case, set "Power Saving" to "Standard".
When Windows is activated, click the "Start" button, move the cursor to "Settings", and click
"Control Panel". Select "Power" from the "Control Panel" to confirm that the "Advanced"
setting has been selected under "Power Management". The default setting is "Advanced".
Action
Please continue normal use
Please continue normal use
Connect the AC adapter to the computer.
Replace the main battery with a fully charged
one.
If recharging is not possible at this time, imme-
diately save any open files on your disk and turn
off the power.
When the indicator remains red for a long time,
proceed with refreshing unless there has been a
sudden change in temperature.
Refer to the Operating Instructions, and make
the proper connections. If the problem persists,
contact the Panasonic Service Center. (Trouble
may have occurred in the battery, charging con-
troller, etc.)
Please wait until refreshing finishes. Press ESC
if you wish to abort.
Refresh the battery pack. (
Please wait until the temperature falls within the
allowable range.
+
Battery Power
P.17)
are pressed.
Standby
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents