10. Remove the sanitary cover from the cap. Ensure the filter mount O‐rings are
protruding from the top of the Cap. Unscrew the Cap from the sump. The
filter mount will s ll be a ached to the cap at this me. Take protec ve
wrapping off of the filter cartridge and place into the sump. Proceed to thread
the Cap (with filter mount s ll a ached) back onto the sump un l ght.
Moisten the O‐rings with water. DO NOT use any
petroleum products to lubricate.
11. Align assembled filter with the lugs on the cap end
facing the front and back of the head. Push the cap end
into the head and then proceed to twist the assembly
clock‐wise 90 degrees to seal. ( A Quarter Turn).
The filter is now installed.
12.Turn on the cold water supply valve and open the fau‐
cet to flush air from the system. Run water for 2‐3
minutes to pre‐condi on the filter. Close the faucet.
The system is now under pressure and can be inspected
for leaks.
Repair any leak before con nuing use.
13.Flush the system twice for 2‐3 minutes before ini al
use.