Compressor data
Compressor current draw at 208-230 VAC, 90 F/32.2 C
Locked rotor amps @ 208-230V
Compressor start winding (208-230 V)
Compressor run winding (208-230 V)
Gearmotor data
Gearmotor current
Gearmotor torque-out (high amp) trip point:
Locked rotor amps
Resistance of windings
208-230 vac gearmotor (Brother):
Red to black: 12Ω
Blue to red: 12Ω
Blue to black: 24Ω
Fan motor data
Fan motor current
Fan motor resistance 100Ω
HCC1010A/W, HCD1010A/W, HCC1410A/W, HCD1410A/W
2.0A @ 208-230 V
2.8A @ 208-230 V
2.8A @ 208-230 V
1.2A @ 208-230 V
1010
6.9A
40.6A
2.74Ω
1.52Ω
1410
12.1A
90A
2.09Ω
0.73Ω
17