Contents Introduction ....................4 Symbols used ............4 1.1.1 Symbols used in the manual ........4 1.1.2 Symbols used on the equipment ......4 Abbreviations ............4 General ..............5 1.3.1 Manufacturer's liability ..........5 1.3.2 Installer's liability .............5 1.3.3 User's liability ............5 Homologations ............6 1.4.1 Certifications ............6 Safety instructions and recommendations ..........7 Safety instructions ..........7 Recommendations ..........7...
Page 3
Contents Starting and stopping the control system ..16 Checking and maintenance ..............17 General instructions ...........17 Safety valve or safety unit .........17 Cleaning the casing material ......17 Checking the magnesium anode .......17 Troubleshooting ..................18 Incidents and solutions ........18 Technical specifications ................19 Solar domestic hot water calorifier ....19 Composition of the NF CESI solar systems packages (For France) ........20...
BSL 200...400 BESL 200...400 1. Introduction Introduction Symbols used 1.1.1. Symbols used in the manual In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.
1. Introduction BSL 200...400 BESL 200...400 General 1.3.1. Manufacturer's liability Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore delivered with [ marking and all relevant documentation. In the interest of customers, we are continuously endeavouring to make improvements in product quality.
BSL 200...400 BESL 200...400 1. Introduction This appliance is not intended to be used by persons (including children) whose physcial, sensory or mental capacity is impaired or persons with no experience or knowledge, unless they have the benefit, through the intermediary of a person responsible for their safety, of supervision or prior instructions regarding use of the appliance.
2. Safety instructions and recommendations BSL 200...400 BESL 200...400 Safety instructions and recommendations Safety instructions DANGER If smoke is released or in case of refrigerant leak: Switch the appliance off. Open the windows. Evacuate the premises. Contact a qualified professional. CAUTION Do not neglect to service the appliance.
Page 9
BSL 200...400 BESL 200...400 2. Safety instructions and recommendations WARNING Never cut the power to the solar control system, even during extended absences. The control system protects the installation against overheating in summer when it is running. WARNING Do not modify the control system parameters unless fully conversant with them.
3. Technical description BSL 200...400 BESL 200...400 Technical description Main parts 3.1.1. Solar domestic hot water calorifier BSL 200...400: External view Expansion vessel Top inspection trap Side inspection plate Solar station Solar regulator Electrical back-up (Option) Safety control unit for the solar circuit All components are checked for leaks and tested in the factory.
BSL 200...400 BESL 200...400 3. Technical description BESL 200...400: External view Expansion vessel Top inspection trap Side inspection plate Solar station Solar regulator Electrical back-up Safety control unit for the solar circuit All components are checked for leaks and tested in the factory.
3. Technical description BSL 200...400 BESL 200...400 3.2.2. Description of the display n System schematics (System-Screen) Solar sensor probe Solar collectors solar heating pump Solar exchanger Solar hot water calorifer Solar sensor Back-up DHW sensor - Back-up M002760-A n Operating indicators Steady symbol Flashing State symbol...
BSL 200...400 BESL 200...400 3. Technical description n LED display LED message Heating pump status Description code PUMPE relay is Regulation operating normally Continuously closed. (System Operating). green Initialisation The installation is in Flashing green/ phase manual mode: Set the regulator to automatic Manual mode mode.
4. Operating the appliance BSL 200...400 BESL 200...400 Operating the appliance Reading out measured values Scroll down the values measured using the ( and ) keys. Parameter Description Remarks Collector temperature S1 sensor. The value TC shows the temperature in °C given by the collector sensor in real time. Calorifier temperature S2 sensor.
BSL 200...400 BESL 200...400 4. Operating the appliance User settings 4.2.1. Setting the time 1. Select the HRE channel with the ( and ) keys. 2. Press the B key for 2 seconds. 3. Set the hour with the ( and ) keys. 4.
4. Operating the appliance BSL 200...400 BESL 200...400 1. Set the 3-position switch to 0. 2. Advance to the last display channel (HRE) with the ( key. 3. Press the ( key for 5 seconds. A setting parameter is displayed, with the symbol T . 4.
BSL 200...400 BESL 200...400 4. Operating the appliance 4.3.2. Setting the thermostatic mixing valve Domestic cold water inlet Domestic hot water outlet The mixing valve is set in the factory for a DHW outlet temperature of 60°C (position 6). To lower this temperature, remove the top cover and turn the wheel anti-clockwise.
5. Checking and maintenance BSL 200...400 BESL 200...400 Checking and maintenance General instructions CAUTION Maintenance operations must be done by a qualified engineer. Only original spare parts must be used. Safety valve or safety unit The safety valve or unit on the domestic cold water inlet must be operated at least once a month to ensure proper operating and to prevent from any overpressure which may that may damage the domestic hot water calorifier.
BSL 200...400 BESL 200...400 6. Troubleshooting Troubleshooting Incidents and solutions Description Checks Solutions The pilot light is off. The current has been cut. Restore the current. 11/06/2012 - 300028413-001-A...
(1) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary flow rate: 2 m 3 /h (2) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Domestic hot water storage: 65 °C BESL 200 BESL 300 BESL 400 Primary circuit: Solar exchanger Maximum operating temperature °C...
BSL 200...400 BESL 200...400 7. Technical specifications BESL 200 BESL 300 BESL 400 Water content litres Top up volume (Electric) litres Solar volume litres Weight Gross weight Net weight Performance Cooling constant Cr Wh/24h·L·K 0.23 0.20 0.18 Maintenance consumption (ΔT=45K) kWh/24h...
Page 22
ER 232 Installation (17°) 100014742 ER 154 On roof 100014076 Roof-integral ER 155 UNO NE 400 - 4 ER 374 EG 101 Installation BESL 400 Electric (2 panels) 100014077 100019142 89807794 (>20°) Roof-integral ER 231 Installation (17°) 100014741 ER 156...
Page 23
BSL 200...400 BESL 200...400 7. Technical specifications CESI System Array of collectors Domestic hot water production Solar fluid INISOL Type of package / package / Volume Back-up package / mounting Reference calorifier Reference (litres) Reference type/Model ER 156 On roof 100014078 Roof-integral ER 157...
8. Warranty BSL 200...400 BESL 200...400 Warranty General You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Page 25
BSL 200...400 BESL 200...400 8. Warranty The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs. The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel.
Page 28
Зубарев переулок, д. 15/1 Бизнес-центр «Чайка Плаза», офис 309 +7 (495) 221-31-51 DUEDI S.r.l. DE DIETRICH THERMIQUE Iberia S.L.U. www.duediclima.it www.dedietrich-calefaccion.es Distributore Ufficiale Esclusivo Av. Princep d’Astúries 43-45 De Dietrich-Thermique Italia 08012 BARCELONA Via Passatore, 12 - 12010 +34 932 920 520...
Need help?
Do you have a question about the BESL 400 and is the answer not in the manual?
Questions and answers