  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS Outdoor unit installation Outdoor installation precaution Install the outdoor unit on a rigid base to prevent increasing noise level and vibration. Determine the air outlet direction where the discharged air is not blocked. In the case that Strong the installation place is exposed to strong wind wind such as a seaside, make sure the fan operating...
  • Page 3: Refrigerant Pipe Connection

    REFRIGERANT PIPE CONNECTION Drain joint installation NOTE: The drain joint differ from appliance to appliance. Fit the seal into the drain joint, then insert the drain joint into the base pan hole of outdoor unit, Base pan hole of rotate 90 to securely assemble them. Drain joint Seal outdoor unit...
  • Page 4: Electrical Work

    ELECTRICAL WORK Tightening Connection Align the center of the pipes. Sufficiently tighten the flare Indoor unit tubing Flare nut Pipings nut with fingers, and then tighten it with a spanner and torque wrench as shown in Fig.58 & 59 Fig.58 Outer Tightening Additional tightening...
  • Page 5: Wiring Connection

    ELECTRICAL WORK Wiring connection Minimum norminal cross-sectional area NOTE: Before performing any electrical of conductors: work, turn off the main power to the system. Rated current of appliance Nominal cross-sectional area (mm ) CAUTIONS 0.75 >3 and <6 Do not touch the capacitor even if you >6 and <10 have disconnected the power for there is still high voltage power on it, or electric...
  • Page 6 ELECTRICAL WORK IMPORTANT: Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. For example, see the following US models: Terminal L1(A) of outdoor must connect with terminal L1 on the indoor unit.
  • Page 7 ELECTRICAL WORK NOTE:please refer to the following figures,if the client want wire by themselves. One-three models: L N S L N S L N S L1 L2 S L1 L2 S L1 L2 S Model B Model B Model A L(1) 1 2(N) S L(1) 1 2(N) S L(1) 1 2(N) S...
  • Page 8 ELECTRICAL WORK One-five models: L N S L N S L N S L N S L N S Model B Model A L(1) 1 2(N) S L(1) 1 2(N) S L(1) 1 2(N) S L(1) 1 2(N) S L(1) 1 2(N) S W 1(L) 2(N) S W 1(L) 2(N) S W 1(L) 2(N) S...