Product Specification - Panasonic CU-RE15JKX Operating Instructions Manual

Hide thumbs Also See for CU-RE15JKX:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION
Indoor Unit
Outdoor Unit
Model
Power/Current
Refrigerant
Cooling Capacity
Heating Capacity
Noise Level
Air Circulation
Product Weight
kg
Dimensions (L x W x H)
Test conditions
1. Cooling: Indoor Dry Bulb Temp. (°C) 27
Wet Bulb Temp. (°C) 19
Heating: Indoor Dry Bulb Temp. (°C) 20
Wet Bulb Temp. (°C) 12 (MAX)
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
38
F566761_EN1.indd
F566761_EN1.indd
章节1:38
章节1:38
[kW]
[A]
[kg]
[kW]
[kW]
JIS C 9612
[<70 dB(A)]
Conditions
[dB(A)]
1m Distance
Max. cooling/
heating
operation
Sound power
[dB(A)]
level
3
[m
/min.]
[kg]
[mm]
CS-RE9JKX
CS-RE12JKX
CU-RE9JKX
CU-RE12JKX
COOL
HEAT
COOL
Single, 230V, 50Hz
Single, 230V, 50Hz
0.700
0.820
1.010
3.45
3.70
4.70
R410A
R410A
0.810
0.970
2.500
3.500
3.300
4.250
42
42
42
47
48
48
53
53
53
60
61
61
13.8
13.8
13.8
9.0
9.0
28
30
848 × 204 × 290
780 × 289 × 540
Outdoor
Dry Bulb Temp. (°C) 35
Wet Bulb Temp. (°C) 24
Outdoor
Dry Bulb Temp. (°C) 7
Wet Bulb Temp. (°C) 6
CS-RE15JKX
CU-RE15JKX
HEAT
COOL
HEAT
Single, 230V, 50Hz
1.120
1.260
1.540
5.20
6.05
7.10
R410A
0.970
4.200
5.300
42
46
47
50
50
51
53
57
58
63
63
64
14.5
14.4
15.3
9.0
36
2008-12-10
2008-12-10
8:47:42
8:47:42

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-re12jkxCu-re9jkxCs-re9jkxCs-re15jkxCs-re12jkx