Fitting your Pump
Duraspeed & Duraspeed 2
Flexible connectors should not be bent. Where possible keep all flexible
connectors vertical.
1. Connect the flexible connectors (1) supplied to the inlet and outlet ports of
the pump. Ensure that the adaptors fitted to the inlets have filters in
position.
1
NOTE: These are designed to effect a leakproof seal with the minimum of
tightening. Hand tight is sufficient, the elbow flexible connectors should be on
the inlets. Ensure not to kink the flexible hoses.
• Either end inlet can be used for hot or cold.
IMPORTANT: The integral fittings on the hose are of the push fit type. All
burrs and rough edges must be removed from the end of the pipe. In the
case of a chrome-plated tube, the first 25mm of plating should be
roughened or removed. Should it be necessary to remove the pipe after
installation, push down the grey collet. (Fig 5a)
2. Connect fitted flex into fused spur outlet, in accordance with the 'Electrics'
chapter.
3. Either by hand or using a coin, rotate boost control (2) fully anti-clockwise, to
maximum mark.
WARNING: Do not fit fuse or switch on mains electrical supply at this point

Varispeed SI

Flexible connectors should not be bent more than 90°. Where possible keep
all flexible connectors vertical.
1. Connect the flexible connectors (1) supplied to the inlet and outlet ports of the
pump. Ensure that the adaptors fitted to the inlet have a filter in position.
NOTE:This is designed to effect a leakproof seal with the minimum of tightening.
Hand tight is sufficient, the long flexible connector should be on the inlet.
Ensure not to kink the flexible hoses.
1
Fig. 6.
Diagram of the Varispeed SI
2. Connect the cable connected to the
3. Either by hand or using a coin, rotate
4
2
3
IMPORTANT: The hoses supplied
with the Varispeed SI should only be
connected
with
compression
fittings. Under no circumstances
should solder fittings be used.
pump to the electric supply, please
refer to the electric section, page 4.
boost control (2) fully anti-clockwise,
to maximum mark.
WARNING: Do not fit fuse or switch
on mains electrical supply at this
point.
NEWTEAM SHOWER PUMPS