Planning your Installation

Electrical

IMPORTANT: This appliance must be earthed. This unit should be installed in
accordance with the 16th Edition IEE Wiring Regulations (BS 7671). If in doubt,
consult a qualified electrician.
The pump must be connected to a 230 volt a.c. supply, fused at 3 amps, via double
pole isolator with a contact separation of at least 3mm.
It is recommended that your installation is protected by a residual current device
(RCD) with a trip rating of no more than 30mA
Connections:
All pumps are supplied with a fitted flex.
The colour of the wires in the cable used for final connection of this appliance
may not correspond with the coloured markings identifying the terminals in
your flex outlet; connection at the appliance and the flex outlet should proceed
as follows.
The wire that is coloured blue must be connected to the terminal that is marked with
the letter N, or coloured black.
The wire that is coloured brown must be connected to the terminal that is marked
with the letter L, or coloured red.
The wire that is coloured green/yellow must be connected to the terminal that is
marked with the letter E, or the earth symbol
, or coloured green.
The
flex
fitted
to
the
pumps
can
only
be
replaced
by
NewTeam,
part no. SP-088-0502.
IMPORTANT: WHEN REPLACING FLEX ENSURE THAT THE CONTROL BOX
COVER IS REPLACED WITHOUT DAMAGING THE NEW CABLES. THE CABLE
mp
GROMMET SHOULD BE USED WHERE THE CABLE ENTERS THE BOX.
VARISPEED SI: BOOST OF GRAVITY HOT ONLY (Fig. 3.)
If you are installing a Varispeed SI, where only a gravity feed is available on the hot
supply, the pump can be used to boost the gravity hot supply only. All storage
capacities and pipe connections (as detailed in fig.2) should be followed. The outlet
feed from the pump should then run to the mixer valve or tap position, ensuring that
the minimum head of 230mm to the handset can be achieved.
UNDER NO CIRCUMSTANCES MUST ANY OF THE PUMPS BE CONNECTED TO
THE MAINS WATER SUPPLY .
NEWTEAM SHOWER PUMPS
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Varispeed siVarispeed 50Duraspeed 2Duraspeed

Table of Contents