Table 1. Scanner Push Button Functions
PRESS
DURATION
Momentary (when
scanner is awake)
Hold, then release
when the beeper
sounds
4 Seconds
8 Seconds
a. By standard default, this function is normally disabled to
prevent accidental activation by users.
b. Users should not perform scanner resets except under the
direction of trained systems support personnel.
6
FUNCTION
Increments volume
Increments tone
Scanner Diagnostics
a
Mode
b
Resets Scanner
COMMENT
Press the push button momen-
tarily to increase speaker vol-
ume. When the loudest volume
is reached, a repeated press of
the push button cycles volume
back to the lowest setting, then
volume increases on subsequent
press(es). Four volume levels
are available.
Press the push button for
approximately 2 seconds, then
release. Each time this is done,
the beeper will sound at one of
three tones. Stop when the
desired tone (high, medium or
low) is sounded.
This mode allows system sup-
port personnel to troubleshoot
problems with the scanner and is
used to determine if it can read
bar codes. Press the button for
eight seconds or cycle power to
exit Scanner Diagnostics Mode
and reset the scanner.
Only system support personnel
should perform a reset.