Maximum MYSTIC Installation Manual

Maximum MYSTIC Installation Manual

Digital barometric pressure and temperature gauge

Advertisement

PR
OPER INST
ALLA
TION IS IMPOR
OR TELEVISION ANTENNA INSTALLER (CHECK WITH YOUR LOCAL BUILDING SUPPLY, OR HARDWARE STORE
FOR REFERRALS). TO PROMOTE CONFIDENCE, PERFORM A TRIAL WIRING BEFORE INSTALLATION.
1
Mount the temperature sensor assembly with the two
large wood screws. Select a location that is protected
from direct sunlight and sheltered from rain and physical
damage. (A north exposure, six feet above the ground
will give the best results.)
Form a drip loop with the wire at least eight inches
below the exit from the sensor and at least eight inches
below the point of entr
exposed wire with insulated cable clips. Run the wire
through the building to the location where the indicator
will be located. Caulk any holes when done.
5
Unplug the AC adaptor and disconnect the wires Mystic is now ready for the final installation.
The adjustment that you have made will always remain intact.
MYSTIC

INSTALLATION

TANT
. IF
YOU NEED ASSISTANCE, CONSUL
Connect the AC adapter to Mystic and plug into outlet. The display will
briefly light up all the indicator lights (self test).
the unit of measurement codes and then will show the barometer function
light and the center display will show a pressure reading. This is the
altitude adjustment mode. Leave it in this mode for now.
y into the b
uilding. Anchor any
4
No
w calibr
ate the barometer for y
pressure for your area by calling a near-by airport or an individual who has a
proper
ly set barometer
screw at the back of Mystic. Turn the screw while observing the pressure read
out on the front of Mystic. Due to the sensitivity of this adjustment, the numbers
on the display may fluctuate during this procedure. It may take a minute to
achie
v
e the exact setting.
right (auto) one time to lock in the setting.
30 Barnet Boulevard
New Bedford, MA 02745
(508) 995-2200
2
3
our altitude
. Inser
t a small scre
w dr
Once the unit is set, mo
.
T A CONTRACT
OR, ELECTRICIAN
Ne
xt the display will show
CAULK
CABLE
CLIP
DRIP
LOOP
.
Obtain the current barometric
iver into the recessed slotted
v
e the toggle switch to the
8"
MIN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MYSTIC and is the answer not in the manual?

Questions and answers

Summary of Contents for Maximum MYSTIC

  • Page 1 (auto) one time to lock in the setting. Unplug the AC adaptor and disconnect the wires Mystic is now ready for the final installation. The adjustment that you have made will always remain intact.
  • Page 2 Auto and releasing it. NOTE: After any full reset, Mystic will display the pressure adjustment mode. It is never necessary to perform the pressure adjustment again. Simply exit this mode by moving the switch to Auto and releasing it.
  • Page 3 However, Rate of Change/Pressure will show "HOLD" for 72 minutes following a "FULL" reset. When the toggle switch is in the center position Mystic will display the infor mation that is indicated b y the function light. All the other functions data are being recorded and stored.
  • Page 4 12 min utes. The Mystic will display the lowest “Wind Chill” reading since the last time that the memory was reset when both the “Low” and “Wind Chill” function LED’s are illuminated simultaneously. For this function to be active you must have a Merlin wind speed and direction instrument and the jumper wire referenced in step 8 of the Mystic installation instructions must be installed.
  • Page 5: Troubleshooting

    MYSTIC TROUBLESHOOTING If at any time the temperature reading seems to be giving you difficulty, prodeed as follows: Remov e the instr ument from the wall. At the back of the indicator, disconnect the sensor wires from minals #4 and #5.
  • Page 6 MYSTIC INFORMATION FOR THE MYSTIC USER Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 7 The shock that you get from touching a doorknob or another person can often be sufficient to damage an instrument. 30 SAMUEL BARNET BOULEVARD NEW BEDFORD, MASSACHUSETTS 02745 U.S.A. TEL. 508.995.2200 WWW.MAXIMUM-INC.COM FAX 800.989.2580...

Table of Contents