System setup
Function
0165
Restore Schedule
Defaults
0170
Select System
Type
If you are not sure of
your heating/cooling
system type or have
other questions,
go to
wifithermostat.com
0173
Heat Pump Type
0180
Heating Fan
Control
0190
Heat Pump
Changeover Valve
(for heat pumps
only)
0200
Back-up Heat
Source
0210
External Fossil
Fuel Kit
0220
1st stage compres-
sor cycle rate
0230
2nd stage com-
pressor cycle rate
0240
Heating Cycle
Rate
0250
Heating Cycle
Rate Stage 2
0260
Heating Cycle
Rate Stage 3
0280
Backlight
69-2733EFS—01
Settings & Options
0
Continue using programmed schedule.
1
Restore thermostat program to energy saving settings
1
Heat/cool: Gas, oil or electric heating with central air conditioning.
Heat pump: Heat pump without backup or auxiliary heat.
2
Heat only without fan: Gas, oil or electric heat without central air
3
conditioning.
Heat only with fan: Gas, oil or electric heat without central air
4
conditioning.
5
Heat only (no fan): Gas, oil or hot water heat without central air
conditioning.
Cool only: Central air conditioning only.
6
Heat pump: Heat pump with backup or auxiliary heating.
7
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2
8
cooling stages (wires on Y and Y2).
9
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1
cooling stage (wire on Y).
Heat/Cool Multiple stages: 1 heat stage (wire on W), 2 cooling stages
10
(wires on Y and Y2).
Heat pump multiple stages: 2 heat stages (wires on W and W2),
11
2 cooling stages (wires on Y and Y2) (no aux. heat).
12
Heat pump multiple stages: 3 heat stages (wires on W, W2, and Aux),
2 cooling stages (wires on Y and Y2) (with aux heat).
0
Air to air heat pump
1
Geothermal heat pump
Gas or oil heat: Use this setting if you have a gas or oil heating system
0
(system controls fan operation).
Electric heat: Use this setting if you have an electric heating system
1
(thermostat controls fan operation).
Cooling changeover valve: Use this setting if you connected a wire
0
labeled "O" to the O/B terminal.
Heating changeover valve: Use this setting if you connected a wire
1
labeled "B" to the O/B terminal.
0
Electric
1
Fossil fuel
0
No
1
Yes
3
Recommended for most compressors
[Other options: 1, 2, 4, 5 or 6 CPH]
5
Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).
9
Electric furnace: Electric heating systems.
Hot water or high-efficiency furnace: Hot water system or gas furnace
3
(more than 90% efficiency).
Gas/oil steam or gravity system: Steam or gravity heat systems.
1
[Other options: 2,4,6,7,8,10,11,12]
0
Backlight off, then on for approximately 8 seconds after keypress.
1
Backlight always on low intensity, full bright after keypress.
4