3.12.2 RETURN TO SERVICE
To return the unit to service after storage, proceed as follows:
1.
Check the tag on the engine for oil viscosity and classification.
Verify that the correct recommended oil is used in the engine
(see "Engine Oil Requirements"). If necessary, drain and refill
with the proper oil.
2.
Check the state of the battery. Fill all cells of unsealed batter-
ies to the proper level with distilled water. DO NOT USE TAP
WATER IN THE BATTERY. Recharge the battery to 100 percent
state of charge, or, if defective, replace the battery.
3.
Clean and wipe the entire generator.
4.
Reconnect the battery. Observe battery polarity. Damage may
occur if the battery is connected incorrectly.
5.
Turn OFF all electrical loads. Add fuel, if necessary, and then
start the engine.
6.
Allow the unit to warm up thoroughly.
7.
Apply electrical loads to at least 50 percent of the unit's rated
wattage capacity.
8.
When the engine is thoroughly warmed up, shut it down.
9.
The generator is now ready for service.