Adjustment - Kenwood RXD-803 Service Manual

Table of Contents

Advertisement

CD player adjustment
No.
ITEM
SETTINGS
1. While pressing the "DISC 3" key, turn the power on to enter the test mode.
2. Load a disc on disc 1 tray.
LASER CURRENT
Test disc
1
CHECK
Note:
Type 4 disc : SONY YEDS-18 Test Disc or equivalent.
LPF: Around 47 kΩ+ 390 pF or so.
Step 1~4 are in Test Mode.
Cassette Deck adjustment
NO.
ITEM
INPUT SETTING
I
Cassette mechanism unit (Adjustment of the REC / PLAY head)
Demagnetization
(1)
and cleaning
Azimuth of the
(2)
REC / PLAY
head
II
PC BOARD ADJUSTMENT
TAPE SPEED
(1)
(NORMAL)
III
PC board adjustment.
PLAYBACK
MTT-256, SCC-1727
(1)
LEVEL
MTT-256U, TCC-120
Adjust the AG for the
(2)
BIAS CURRENT
output of the DECK to
become 12.5KHz -20dBs.
400Hz/12.5kHz (AC-224)
Measurement Equipment Connections
+
-
R
L
FRONT
SPEAKERS
(6-16 )
SUPER
WOOFER
PRE OUT
CENTER SPEAKER
( 6-16 )
-
+
L
R
AG
AC voltmeter
SURROUND SPEAKERS
(12-16 )
(A)

ADJUSTMENT

INPUT
OUTPUT
SETTINGS
Connect the DC
voltmeter to
Type 4
CN6(pin1 and 2)
on X32.
OUTPUT
CASSETTE TAPE
SETTING
Demagnetization,
SCC-1727
TCC-153
(B)
MTT-114
10kHz, -10dB
TCC-110
MTT-111
(B)
SCC-1727
3kHZ
MTT-150
400Hz
(B)
315Hz
315 Hz
(A)
(B)
ANTENNA
AM
GND
FM
75
6CH.
INPUT
L
R
FRONT
SURROUND
CENTER
SUB
WOOFER
X13, CN1
Oscilloscope
DIGITAL
OUT
OPTICAL
31
L-PLAY
AC 110-
30
120V~
AC 220-
29
240V~
R-PLAY
28
GND
(B)
RXD-803/803E/853/853E/A83
PLAYER
ALIGNMENT
SETTINGS
Press the
PLAY/PAUSE key,
then confirm that the
display is 03 or 05.
ALIGNMENT
DECK SETTING
POINTS
Recording
Power : OFF
head, erase
head, capstan
cleaning, PLAY
pinch roller
PLAY
RVS
FWD
PLAY
VR5
VR 3 (L)
PLAY
VR 4 (R)
VR 1 (L)
REC PLAY
VR 2 (R)
AC voltmeter
Frequency counter
ALIGN FOR
POINTS
0.5±0.2V
ALIGN FOR
0dBs = 0.775V
Demagnetize the REC / PLAY head
with the head eraser. Clean the REC /
PLAY head, erase head, capstan and
pinch roller using a cotton swab slightly
damped with alcohol.
Adjust the output to maximum and
adjust the azimuth adjustment screw
for the Lissajours waveform pattern of
the oscilloscope to become close to a
45ß straight line.
Adjust the tape speed so that 3kHz is
obtained at the center of the tape.
Adjust the playback output to -2.5dBs.
Adjust the playback output to -5.5dBs.
Adjust the playback output to -1.5dBs.
Record 400Hz and 12.5kHz alternately,
and adjust the bias current adjustment
potentiometer for the playback levels to
become the same.
FIG.
FIG.
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rxd-853eRxd-803eRxd-853Rxd-a83

Table of Contents