Installation - Marcucci cds-7 deluxe User Manual

Table of Contents

Advertisement

Available languages

Available languages

Installation

Caution:
Switch off the electric source before installing the thermostat. We recommend that the
installation should be performed by a trained personnel.
1. Select a suitable location for the thermostat
The location of the thermostat can greatly affect its performance. If it is located at
where circulate air can not reach or exposed to direct sun light, it will not adjust the
room temperature properly.
To ensure proper operation, the thermostat should be installed at an in-side wall with
freely circulating air. Find a place where your family usually cccupied.
Avoid close to some heat generating appliance (e . g. TV, heater , refrigerator) or
exposed to direct sun light. Do no install near a door where the thermostat will suffer
from vibration.
2. Wiring
Wiring terminals are at the back of the thermostat. You can find three terminals which
labeled COM, NO and NC. It is a typical single-pole, double throw(SPDT) contact.
In most case COM and NO are used.
Please wiring the thermostat to you system as the following drawing.
3. Mounting on the thermostat
Use the template provided , drill two 06mm holes on the wall.
Insert the wall anchors and tighten the left screw with 3mm clearance. Fix the ther-
mostat by putting it over the screwhead and slide it rightward(note the keyhole like
opening at the back of the thermostat). Tighten the remain screw to lock it in place.
Note:
If the wall is made wood, there is no need to use the wall anchors . Drill two Ø2.7mm
holes instead of 06mm.
Specification
Temperature measurement range
Temperature control range
Temperature accuracy
Clock accuracy
Program
Switch span
Control mode
Minimum air – con. cycle time
Switching
Battery
Operating temperature
Storage temperature
Operating humidity
0 – 40°C (0.5°C step)
5 – 30°C (0.5°C step)
+/ - 0.5°C
+/ - 70 seconds / month
10 preset, 10 user - define
1°C or 2°C
Heating or cooling system
5minutes + 45 second
24VAC 6A resistive
230VAC 50Hz 6A resistive
2 x LR6 alkaline battery
0 – 45°C
- 20 – 60°C
5 – 90% non-condensing

Advertisement

Table of Contents
loading

Table of Contents