Network
The Network screen allows setting the screen name and setup of
an IP address for the TPT650. As with most IP based products
the TPT650 may obtain an IP address automatically using the
DHCP setting. It is also possible to assign a Static IP address
which may be more desirable for most applications. The current
IP address, DHCP or Static, is displayed on this screen.
Device Name
The "Device Name" is the name that will identify the TPT650 in
Design Center for exporting. It may be changed from "TPT650
(serial number)" to whatever is desired. It is recommended that
the name match the name used in Design Center.
To enter the name, simply touch the Device Name section
of the table to open the soft keyboard screen then enter
the name and touch Save.
DHCP
To set a DHCP address, simply click the DHCP button
and then click the X to exit the configuration screen.
Static
To set a Static IP address, simply click the Static button
and then click on the IP Address section of the table.
A soft keyboard is opened allowing the static IP address
to be entered.
Click Save when finished
Additional IP settings are also available for more
advanced network configurations
Netmask
o
Gateway Address
o
Preferred DNS
o
Alternate DNS
o
Most "home" networks will only need a DHCP or Static IP
address as long as the TPT650 is on the same network as the
InFusion Controller.
Sound
The Sound configuration screen allows the Volume, Frequency
and Duration of the sound when buttons are touched.
Experiment with settings on this screen to obtain a desired
sound for buttons.
Front Of TPT650
On the front of the TPT650 are two hard buttons that may be
assigned to any task in Design Center like a keypad button.
There is also a built-in Light sensor and Motion sensor, behind
the translucent diffuser in the front, bottom center of the screen,
for the screens operation (see Setup Screens above). The two
very small holes on each side of the Sensor lens balance the
design. The left hole contains a Reset button.
Note: the Reset button requires a long -
wire, e.g., a straightened paper clip would be ideal. The hole
contains a plastic tube to guide the wire preventing it from
wandering when inserted to reset the station.
Video/Audio Connections
A/V connector cables are available from Vantage, part number
VDA-0176.
To build your own A/V connector cables please study drawings
below. CAT-5 wire should be used when building A/V cables.
Note: A/V cables should not exceed 200ft.
Reset
To reset the TPT650 to Boot Loader Screen (below) while
holding in hard buttons 1 and 2, press and release the Reset
button in the left hole. Do this if the screen is in an unstable
mode and communication cannot be established. When the
screen boots to the Boot Loader Screen communication should
be possible again allowing firmware updates. Pressing Reset
without holding buttons 1 and 2 simply resets the screen.
Boot Loader
The Boot Loader screen is a root level boot screen and may be
used when simply communicating with the screen at a
rudimentary level (Touchscreen Designer Exports are not
possible while in this mode). It also displays a green checkmark
or red X for each section of the TouchScreen's operational
status. This is valuable for troubleshooting. Reset the screen to
exit the Boot Loader Screen.