How To Discharge The E. Capacitor On Capacitor P.c.b. Unit - Panasonic DMC-GH3P Service Manual

Table of Contents

Advertisement

1.4.

How to Discharge the E. Capacitor on Capacitor P.C.B. Unit

CAUTION:
1. Be sure to discharge the E. Capacitor on Capacitor P.C.B. Unit.
2. Be careful of the high voltage circuit on Capacitor P.C.B. Unit when servicing.
[Discharging Procedure]
1. Peel the Battery Case Sheet.
2. Remove the Capacitor Cover.
3. Unscrew the 2 screws (O).
4. Remove the Capacitor P.C.B. Unit.
5. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1kΩ /5W).
(An equivalent type of resistor may be used.)
6. Put the resistor between both terminals of E. Capacitor on Capacitor P.C.B. Unit for approx. 5 seconds.
7. After discharging, confirm that the E. Capacitor voltage is lower than 10V by using a voltmeter.
Fig. F1
5