Lightning Protection Zones

When the ODU is installed on a mast, tower or wall, it may be in one of two possible lightning
protection zones:
• Zone A: In this zone a direct lighting strike is possible. Do not mount the ODU in this zone.
• Zone B: In this zone, direct EMD (Lightning) effects are still possible, but mounting in this
zone significantly reduces the possibility of a direct strike. Mount the ODU in this zone.
Recommended
Zone A
Zone B
The following protection requirements are mandatory:
• The ODU must be earthed
• Screened CAT 5e cable must be used
• Surge arrestor of type PTP-LPU must be installed at building entry
• There must be an earth connection at building entry
More information:
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Protect Your Installation
NOT Recommended
Zone A
Zone B
PTP 300 Series User Guide
or PTP 500 Series User Guide
Finial
Zone A
Zone B
Section:
"Lightning Protection"
3
Recommended