Vitodens 100 WB1B Wiring using DHW Connection

IMPORTANT
This cannot be used in conjunction with DHW or
CombiPLUS equipped boilers.
Viessmann AirflowPLUS
Connection Board
A
Thermostat
Power Pump Module (PPM)
A Heating circuit control connection.
Connect call for heat (K2) relay of the air handler to the
DHW connection (X4 terminals 1 and 2) of the Vitodens
100 WB1B power pump module.
In a system where the DHW contact is not used, the DHW
contact may be used as a second set point (this set point
is not affected by outdoor reset). Refer to page 40 for
additional information.
Installation
23