Specifications - Empire Comfort Systems DVCP36PP3 SERIES Installation Instructions And Manual

Table of Contents

Advertisement

Input BTU/Hr Maximum
Input BTU/Hr Minimum
KWH (Maximum)
KWH (Minimum)
Orifice
Air Shutter Opening*
Height without standoff
Width
Depth
Gas Inlet Shutoff Valve (pipe)
Venting
*NOTICE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
Page 6

SPECIFICATIONS

NATURAL GAS
PENINSULA
MODELS
34,000
23,000
9.96
6.74
#33
3/16in
(1/8in w/40ft. Vertical Vent,
flue restrictor installed)
39-1/2in
42-1/4in
24in
1/2 NPT
5" x 8", See Page 26
GAS SUPPLY PRESSURES
GAS TYPE
MAXIMUM
NAT
14
LP
14
SEE-THRU
MODELS
34,000
23,000
9.96
6.74
#33
3/16in
(1/8in w/40ft. Vertical Vent,
flue restrictor installed)
39-1/2in
45-1/2in
24in
1/2 NPT
5" x 8", See Page 26
MINIMUM
MANIFOLD
4.5
11
LP
PENINSULA
SEE-THRU
MODELS
32,000
26,500
9.38
7.76
#51
FULLY OPEN
FULLY OPEN
39-1/2in
42-1/4in
24in
1/2 NPT
5" x 8", See Page 26 5" x 8", See Page 26
3.5
10
MODELS
32,000
26,500
9.38
7.76
#51
39-1/2in
45-1/2in
24in
1/2 NPT
36092-2-0316