10
190E2 LCD
To lock/unlock OSD FUNCTION(User Mode)
The OSD function can be locked by pressing"OK"button(1) for more than 10
seconds, the screen shows following windows for 4 seconds. Every time
when you press"OK" button, this message appears on the screen
automatically .
Unlock OSD function
Unlocked OSD function can be released by pressing "OK" button for more
than 10 seconds again.
1). Turn off monitor.
2). [Push "EXIT" & "MENU" buttons at the same time and hold them]+[Press
"power" button until comes out "Windows screen" ] => then release all
buttons
3).Press "MENU" button, wait until the OSD menu with Characters
"MERIDIAN 190E2+ V0.4 2010-06-14" (below OSD menu) come on the
Screen of the monitor.
Factory Mode indicator
Factory Menu
Cursor can move on gray color area
Hot key function: by pressing " UP " and " DOWN " key Simultaneously at
User Mode (or Factory Mode) (PS: The Of fset R G B function can be used
on reduce or eliminate snowy noise on the background when the resolution
of video signal is 1680*1050vertical 60Hz. Slightly increase or decrease the
value until snowy noise completely disappear .
Step 1 : Access Factory Mode then enter Factory Menu.
Step 2 : By pressing " UP" and "
"MENU then press " UP" and
"DOWN
Step 3 : Disconnect interface cable between Monitor and PC.
After 3 seconds,
bring up:
repeatly
Connect Signal cable again=> go back to normal display
DOWN
" key to Burning Icon. Press
" key to turn on Aging Mode.

Advertisement