Temperature Control Operation

For any temperature setting, outputs will be turned off/on based on cut-in/cut-out temperature determined
by resistance levels of freezer or refrigerator thermistors.
Freezer Thermistor (NTC)
As temperature decreases, resistance increases. As temperature increases, resistance decreases.
Note: Open thermistor or thermistor circuit or a shorted thermistor will result in freezer continuing to cool
with error code displayed. The section will call for cooling 100 percent of time except during defrost cycle
Deg F
Deg C
-24
-31
-22
-30
-20
-29
-18
-28
-16
-27
-15
-26
-13
-25
-11
-24
-9
-23
-8
-22
-6
-21
-4
-20
-2
-19
0
-18
1
-17
3
-16
5
-15
7
-14
9
-13
Freezer temperature setting and thermistor value will determine if compressor/condenser fan and evaporator fan
switches are open or closed. Compressor/ condenser fan switch must be open for 6 minutes before switch can close
again (compressor dwell time). Refrigerator temperature setting and thermistor value will determine if fresh food
switch is open or closed. Cut-out and cut-in temperature values must be reached and maintained for 15 seconds
before output state will change (digital delay). Freezer control calibration can be adjusted in Program Mode A.
©2012 Viking Preferred Service
K-Ohms
Deg F
565
10
531
12
499
14
469
16
441
18
415
19
391
21
368
23
347
25
327
27
308
28
291
30
274
32
259
34
245
36
231
37
218
39
206
41
195
43
Deg C
K-Ohms
-12
185
-11
175
-10
165
-9
157
-8
148
-7
141
-6
133
-5
126
-4
120
-3
114
-2
108
-1
103
0
97
1
93
2
88
3
84
4
80
5
76
6
72
Operation
Deg F
Deg C
K-Ohms
45
7
46
8
48
9
50
10
52
11
54
12
55
13
57
14
59
15
61
16
63
17
64
18
66
19
68
20
70
21
72
22
73
23
75
24
77
25
69
65
62
59
56
54
51
49
47
44
42
41
39
37
35
34
32
31
30
11