Standby Electricity Saving - Daikin 3MXM40M2V1B Installation Manual

Single-split inverter series
Hide thumbs Also See for 3MXM40M2V1B:
Table of Contents

Advertisement

Wiring
CAUTION
Precautions to be taken for power supply wiring. When using
stranded wires, make sure to use the round crimp-style terminal
for connection to the power supply terminal
Flat washer
Screw
A
Round
crimp-style
terminal
¨
When connecting the inter-unit wires to the terminal block using a single core wire,
be sure to curl the end of the lead. Improper work may cause heat and fires.
Good
Stripping wire at terminal block
Ground
This air conditioner must be grounded. For grounding, follow all local, and state electrical codes.

Standby Electricity Saving

3MXM40M, 3MXM52M, 3AMX52M only
The standby electricity saving function turns off power supply to the outdoor unit and sets the indoor unit into
standby electricity saving mode, thus reducing the power consumption of the air conditioner.
The standby electricity saving function works on the following indoor unit.
For FTXM, FTXP, FTXJ type
CAUTION
• The standby electricity saving function cannot be used for models other than the specified ones.
Procedure for turning on standby electricity saving
function
1) Check that the main power supply is turned off. Turn it
off if it has not been turned off.
2) Remove the stop valve cover.
3) Disconnect the selective connector for standby
electricity saving.
4) Turn on the main power supply.
CAUTION
• Before connecting or disconnecting the selective connector for standby electricity saving, make sure that the main power
supply is turned off.
• The selective connector for standby electricity saving is required if an indoor unit other than the above applicable one is connected.
English
Good
Strip wire end
to this point.
Wrong
Round crimp-style
terminal
Screw
Round crimp-
style terminal
Flat washer
Wrong
Arrow view A
Excessive strip length
may cause electric shock
or current leakage.
Good
Standby electricity saving
function off.
The standby electricity saving function is turned off before shipping.
Screw
Flat washer
Round crimp-
style terminal
• Make sure that the
earth wire between
the pull relief and
terminal is longer
than the other
wires.
Wrong
A
Standby electricity saving
function on.
Stranded
wire
1-3
B
A<B
14

Advertisement

Table of Contents
loading

Table of Contents