2. Normal Defrost Mode
PRECOOL
HEATER
DEFROTING
PAUSE
FAN DELAY
Normal Mode
Division
Compressor
Freezer Fan
Refrigerator Fan
Defrsot Heater
Time
3. Forced Defrost Mode
1) How to start
( Basic Models Only )
; Press the REF. SET button 5 times while pushing the FRZ. SET button.
( Dispenser Models Only )
- Press the LOCK button.
- Press the Refrigerator Set button 5 times while pushing the Freezer Set button.
2) Except PRECOOL, steps are same as above 2. Normal Defrost Mode.
1) PRECOOL
- Compressor runs ( to cool down the freezer compartment prior to heater switch on )
for 50minutes or until Freezer sensor temperature reaches -27C
2) HEATER DEFROSTING
- Defrost heater is switch on until Defrost Sensor temperature reaches 13C.
- Heater operation time
; 30 seconds - Heater is ON free of Defrost Sensor.
; 30 minutes - When Defrost Sensor is malfunction. ( D1 error )
; 80 minutes - Heater maximum operation time. ( F3 error )
3) PAUSE
- After Defrost Heater switch OFF, Compressor dosen't run within 7 minutes.
4) FAN DELAY
- Freezer & Refrigerator fan switch on after 5miunuts' cmopressor running.
PRECOOL
HEATER DEFROST
ON
OFF
ON
OFF
Control
OFF
Off
30min ( D1 error )
50min
80min ( F3 error)
PAUSE
OFF
OFF
OFF
ON
OFF
7min
12
FUNCTIONS ( Defrost Mode )
FAN DELAY
ON
OFF
OFF
OFF
5min